Nidek Medical Mark 5 Nuvo MB User Manual

Nidek Medical Mark 5 Nuvo MB User Manual

Oxygen concentrator with modular bed (mb)

Advertisement

USER'S GUIDE
Mark 5 Nuvo
NUVO, NUVO 8 & NUVO 10
OXYGEN CONCENTRATOR
[Original language is English]
Federal Law (US) restricts this device to sale
by, or on the order of, a licensed physician.
This oxygen concentrator should be used
only under the supervision of a licensed
physician.
GLOSSARY OF SYMBOLS ..........................................1
GENERAL SAFETY GUIDELINES ............................2
I.
DESCRIPTION .......................................................2
I.1. Front panel (Fig. I. 1) ........................................... 3
I.2. Rear panel (Fig. I. 2) ..................................................3
II. STARTING-UP / INSTALLATION .......................3
II.1. Use in direct oxygen therapy .....................................3
III. CLEANING-MAINTENANCE .............................4
III.1.Cleaning ....................................................................4
III.2.Everyday disinfection ....................................................4
III.3.Maintenance ..............................................................4
: ON (power switched on)
: Off (power switched off)
: Type B device
: Class II protection
: Do not expose to open flames
2010-2324CE Rev A
with Modular Bed
CONTENTS

GLOSSARY OF SYMBOLS

November 2013
0413: Complies with the 93/42/ EEC directive
certified by the approved organization no 0413.
Danger: Do not smoke when using oxygen or when
near this device.
IV.USEFUL INFORMATION ......................................... 4
IV.1. Accessories and spare parts ....................................... 4
IV.3. Operating principles .................................................. 5
IV.4. Alarms - Safety devices ............................................ 5
IV.5. Oxygen Monitor (OCSI) function ........................... 5
IV.6. Technical characteristics ........................................... 5
IV.7. Standards ................................................................... 6
IV.8. Method for disposing of waste .................................. 6
IV.9. Method for disposing of device................................. 6
IV.10.Troubleshooting......................................................... 7
V. EMC, Electromagnetic statements ...........................8-9
: Do not use oil or grease
: Technical information
: Consult the accompanying documents
: Keep in the vertical position
: Fragile - handle with care
: Oxygen concentration warning light
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Mark 5 Nuvo MB and is the answer not in the manual?

Questions and answers

Summary of Contents for Nidek Medical Mark 5 Nuvo MB

  • Page 1: Table Of Contents

    USER'S GUIDE Mark 5 Nuvo with Modular Bed NUVO, NUVO 8 & NUVO 10 OXYGEN CONCENTRATOR [Original language is English] 0413: Complies with the 93/42/ EEC directive Federal Law (US) restricts this device to sale certified by the approved organization no 0413. by, or on the order of, a licensed physician.
  • Page 2: General Safety Guidelines

    (rear filter unobstructed). This device complies with the requirements of the FDA Quality The Mark 5 Nuvo MB must only be used for oxygen System Regulation and the 93/42/EEC uropean directive therapy and only on a medical prescription. The...
  • Page 3: Front Panel (Fig. I.1)

    . STARTING UP / INSTALLATION II.1. Use in direct oxygen therapy a. Ensure that the switch (1) is in the (OFF) position. b. If used with a humidifier: Unscrew the flask and fill it with water up to the line (see humidifier instructions). Then screw the lid on the humidifier flask until there are no leaks.
  • Page 4: Cleaning-Maintenance

    No special maintenance needs to be carried out by the patient. Your equipment supplier performs periodic main- Only the outside of the Mark 5 Nuvo MB is to be cleaned, tenance operations to assure continued reliable service from the Mark 5 Nuvo MB.
  • Page 5: Iv.3. Operating Principles

    (from the column "in production"). In this way, when one column is in production, the other is in When the Mark 5 Nuvo MB is started, the indicator lights a nitrogen desorption or "regeneration" phase. The oxygen...
  • Page 6: Iv.7. Standards

    6.9 kPa (1 psig) is applied to the output of the device. The maximum outlet pressure is: 7psig for 5 l/min, 15 psig for 8 All waste from the Mark 5 Nuvo MB (patient circuit, filter, l/min, and 20 psig for 10 l/min.
  • Page 7: Iv.10.Troubleshooting

    NOTES PREVENTIVE MAINTENANCE: a. Wash cabinet filter weekly. ------------------------------------------------------ b. Inspect inlet air filter at each patient visit. ------------------------------------------------------ Replace filter annually, or more often depending on ------------------------------------------------------ environment. ------------------------------------------------------ c. Check oxygen concentration every 15,000 hours or ------------------------------------------------------ 3 years to verify the continuing OCSI function. ------------------------------------------------------ The manufacturer’s instructions for the preventive ------------------------------------------------------...
  • Page 8 IV. 10. Troubleshooting. Observations Possible Causes Solutions The I-0 (ON/OFF) button is in the Power cable (9) is not correctly Check the cable connection. “I” (ON) position but the device plugged into the wall outlet. does not operate. The audible alarm sounds intermit- Power failure.
  • Page 9: Emc, Electromagnetic Statements

    V. EMC, Electromagnetic Statements 2010-2324CE Rev A November 2013...
  • Page 10 NOTES ------------------------------------------------------------------------------------------------------------------- ------------------------------------------------------------------------------------------------------------------- ------------------------------------------------------------------------------------------------------------------- ------------------------------------------------------------------------------------------------------------------- ------------------------------------------------------------------------------------------------------------------- ------------------------------------------------------------------------------------------------------------------- ------------------------------------------------------------------------------------------------------------------- ------------------------------------------------------------------------------------------------------------------- ------------------------------------------------------------------------------------------------------------------- ------------------------------------------------------------------------------------------------------------------- ------------------------------------------------------------------------------------------------------------------- ------------------------------------------------------------------------------------------------------------------- ------------------------------------------------------------------------------------------------------------------- ------------------------------------------------------------------------------------------------------------------- ------------------------------------------------------------------------------------------------------------------- ------------------------------------------------------------------------------------------------------------------- ------------------------------------------------------------------------------------------------------------------- November 2013 010-2324CE Rev A...
  • Page 11 NOTES ------------------------------------------------------------------------------------------------------------------- ------------------------------------------------------------------------------------------------------------------- ------------------------------------------------------------------------------------------------------------------- ------------------------------------------------------------------------------------------------------------------- ------------------------------------------------------------------------------------------------------------------- ------------------------------------------------------------------------------------------------------------------- ------------------------------------------------------------------------------------------------------------------- ------------------------------------------------------------------------------------------------------------------- ------------------------------------------------------------------------------------------------------------------- ------------------------------------------------------------------------------------------------------------------- ------------------------------------------------------------------------------------------------------------------- ------------------------------------------------------------------------------------------------------------------- ------------------------------------------------------------------------------------------------------------------- ------------------------------------------------------------------------------------------------------------------- ------------------------------------------------------------------------------------------------------------------- ------------------------------------------------------------------------------------------------------------------- ------------------------------------------------------------------------------------------------------------------- 2010-2324CE Rev A November 2013...
  • Page 12 EU Representative mdi Europa GmbH Langenhagener Str. 71 30855 Hannover-Langenhagen Germany Tel: +49-511-39-08 95 30 Nidek Medical Products, Inc. 3949 Valley East Industrial Drive Fax: +49-511-39-08 95 39 Birmingham, Alabama 35217 U.S.A. info@mdi-europa.com Tel: 205-856-7200 Fax: 205-856-0533 www.mdi-europa.com November 2013...

This manual is also suitable for:

Mark 5 nuvo 10Mark 5 nuvo 8

Table of Contents