Product Specifications

Electrical
EC/mV: 16V to 32V (24V nominal) ** Startup/Normal values **
Operating Voltage
IR: 18V to 32V (24V nominal) ** Startup/Normal values **
Configuration
XNX EC
Power
XNX mV
Consumption
XNX IR (Optima)
XNX IR (Excel)
Crimp style pluggable with retaining screws, 12-28 AWG (2.5 to 0.5mm
with Shorting Jumpers: 14-28 AWG (2.0 to 0.5mm
Termination
NOTE:
To maintain EMC integrity, wiring must be shielded by either an integral
shield or run through conduit or pipe. Shield must provide 90% coverage.
Standard
Optional
Signal
20 mA
Cable Ports
5 – (2 right, 2 left, 1 bottom) Available in ¾" NPT, or M25
Recommended
See the
Distance Considerations for Installation
Cable
Unpowered
(Real Time Clock) 3 years at rated storage temperature
battery life
Construction
Material
Marine grade aluminum alloy or SS316. 5-coat painted finish.
Dimensions
159 x 197 x 113.8 mm / 6.138 x 7.75 x 4.48 inches
2.27 kg (5 lb) Aluminum
Weight
5 kg (11 lb) Stainless
Mounting
Specifications
Max Power
Inrush
6.2 w
<1A, <10ms@24VDC
6.5 w
<750mA <2ms@24VDC
9.7w
<1A, <10ms@24VDC
13.2w
<1A, <10ms@24VDC
)
2
HART over 3-wire 4-20 mA (sink, source, or isolated)
Modbus over RS-485
HART over 3-wire 4-20mA (sink, source, or isolated)
compliant with NAMUR NE43
section.
Integral Mounting Lugs for Wall- or Optional Pipe-Mount, Optional Wall/
XNX
Enclosure
®
Ceiling Bracket
User Interface
Standard
Custom Backlit LCD, magnetic wand operation of local user interface
Optional
HART Handheld with IS Port
Environmental - Transmitter Operating
IP Rating
IP66
Transmitter: -40°C to +65°C (-40°F to +149°F)
2
)
Temperature*
MPD**-CB1: -40°C to +65°C (-40°F to +149°F)
MPD**-I**: -20°C to +50°C (-4°F to +122°F)
Humidity
0 to 99% RH non-condensing
Pressure
80 kPa to 120 kPa
Air Speed
0-6 m/sec
*Operating temperatures will be limited by the sensors. See
Mutual
Verified;
EC Sensor Performance Data, DEKRA EXAM
information.
Environmental - Transmitter Storage
Temperature
-40°C to +65°C / -40°F to +149°F
Humidity
0 to 99% RH non-condensing
138
EC Sensor Performance Data, Factory
Verified; and
Other EC Sensors
for more

Advertisement

Table of Contents
loading