8. Attach the cable to the remote terminal box via the gland
provided.
9. Make the connections as shown in the
sensor mounting kit
10. Fit the Terminal box lid.
11. Plug the sensor into the socket at the bottom of the terminal
box.
12. Fit the sensor retainer, tighten the locking screw, and fit
the weatherproof cover.
13. Calibrate the sensor following the procedure in the
and Span Calibration for EC Sensors, mV Sensors, and
Searchpoint Optima
Installation and Operation
Installing a remote
illustration on the next page.
section.
Connections
Pin # Color
1
2
3
4
Zero
5
6
Sensor Mounted to Remote Sensor Kit
45
Yellow
Green
Blue
White
Red
Black
Sensor Cartridge
Sensor Retainer
Weatherproof Cap
Figure 42. Installing a remote sensor mounting kit