XNX Universal Transmitter
Informational Messages
Number
Description
I001
Unused
I002
Force Relay Mode Started
I003
Force Relay Mode Ended.
I004
Force mA Mode Started
I005
Force mA Mode Ended
I006
Short-Term Inhibit Started
I007
Short-Term Inhibit Ended
I008
Long-Term Inhibit Started
I009
Long-Term Inhibit Ended
I010
mA Output Recalibrated
I011
Bump Test Started
I012
Bump Test Timed Out
I013
Bump Test Completed Concentration < Al1 Peak concentration observed
Bump Test Completed
I014
Al1 < Concentration < Al2
I015
Bump Test Completed. Al2 < Concentration Peak concentration observed
I016
Zero Calibration Successful
I017
Zero Calibration Failed
I018
Calibrate Span Successful 1 of 2
I019
Calibrate Span Successful 2 of 2
I020
Calibrate Span Failed
I021
Calibrate Span Timeout
I022
Password Changed
I023
Performing Soft Reset
I024
Alarms Configured Latching
I025
Alarms Configured Non-Latching
Alarm Relays Configured Normally
I026
Energized
Warnings/Faults
Contents of Data Field
Bitpattern for relays. (E.G. 7.0 ==All)
N/A
Force current. (E.G. 20.0)
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
Peak concentration observed
N/A
Error code
Percent change in span factor from previous
Absolute span factor
Error code
N/A
1,2 or 3 (access level)
N/A
N/A
N/A
N/A
Number
Description
Alarm Relays Configured Normally De-
I027
Energized.
I028
Fieldbus Address Changed
I029
Fieldbus Speed Changed
I030
Sensor Type Changed
I031
Gas Selection Changed
I032
Time For Beam Block Fault Changed
I033
Time For Fault Detection Changed
I034
Level For Low Signal Fault Changed
I035
Invalid Path Length Written
I036
Path Length Changed
I037
mA for Inhibit Changed
I038
mA for Warning Changed
I039
mA for Overrange Changed
I040
mA for Fault Changed
I041
mA for Low Signal Changed
I042
mA for Blocked Beam Changed
I043
Concentration for mA Full Scale Changed
I044
Instrument Id Changed
I045
Measuring Units Changed
Alarm 1 Reconfigured for Increasing
I046
Concentrations
Alarm 1 Reconfigured for Depleting
I047
Concentrations
Alarm 2 Reconfigured for Increasing
I048
Concentrations
Alarm 2 Reconfigured for Depleting
I049
Concentrations
I050
Alarm 1 Value Changed
I051
Alarm 2 Value Changed
I052
Clock Set
135
Contents of Data Field
N/A
New address (e.g. 15)
New speed (e.g. 19200)
iCurrentCalGlobalID
iCurrentCalGlobalID
iBlockFltTime
iOtherFltTime
fLowSignalLevel
fPathLen
fPathLen
f_mA_Flt_Step[0]
f_mA_Flt_Step[1]
f_mA_Flt_Step[2]
f_mA_Flt_Step[3]
f_mA_Flt_Step[4]
f_mA_Flt_Step[5]
fDisplayRange
N/A
iMeasurementUnits
N/A
N/A
N/A
N/A
fAlarmThres[0]
fAlarmThres[1]
N/A

Advertisement

Table of Contents
loading

Table of Contents