22.14 Junction Box
GENERAL SPECIFICATION
Mechanical
Dimension
Mass
Environment
Operational Temperature
Operational Humidity
Vibration
EMC
Ingress Protection Rating
Power
Power
Input Voltage
Power Consumption
Over Current Protection
FUNCTIONAL SPECIFICATION
Interface
IEC61162-1
IEC61162-2
IEC61162-450
Dry Contact Output (N.C/N.O
selectable)
Dry Contact Input
Ingress Protection Rating
FUNCTIONAL SPECIFICATION
GYRO
STEP
SYNC
RATIO
OUTPUT
LOG
PULSE
RATIO
OUTPUT
FUNCTIONAL SPECIFICATION
Interface
Isolated Input
Input Signal Range
Section 22 Specifications
NQE-1143: Junction Box
Width 400 x Depth 86 x Height 261.5 (mm)
3.8kg
-15C to +55C
40C RH 93%
Sweep 2Hz to 13.2Hz at ± 1mm, 13.2Hz to 100Hz at 7m/s
and for 2h on each resonance, otherwise 2h at 30Hz in all
three axes
IEC60945-Ed4.0
Front : IP20
21.6 to 31.2 VDC
48W MAX
3A 2, 15A 1 Mini Blade Fuse
Yes
CMH-2370: Serial LAN Interface Circuit
8 input / 8 output
2 input / 2 output
1 (100BASE-TX)
8 (32V, 0.8A sink MAX)
8 (5V, 50mA source MAX)
Front : IP20
CMJ-554: Gyro Interface Circuit
22 to 70 VDC
24 to 115VAC, 50/60/400Hz
36/90/180/360
THS (50Hz)
Dry contact: 30V(max), 50 mA(max)
Voltage signal: 0-50V (threshold level is 2V)
100/200/400/800 [P/NM]
VBW (1Hz), VLW (0.1Hz)
CMJ-556: Analog Option Circuit
4
-10 to 10 VDC or 4 to 20 mA
22-16
2