Troubleshooting and FAQs continued
Why does my door creep closed with Plunger fully depressed?
• Check condition of the Ferrule. Repacement Ferrules are available from your supplier or
contact the Technical Help line
2
• Check Dorgard X
is positioned low enough that the Ferrule makes good contact with the
floor when the Plunger is depressed. A vertical Plunger movement of 10-15mm is ideal.
Re-position as necessary or fit the Floorplate supplied
• Check that the overhead door closer does not shut the door with excessive force. If so, fit
a Floorplate supplied or adjust pressure on overhead closer (refer to manufacturers
instructions)
• Check that the Ferrule has enough grip on the floor surface i.e. floor surface is not too
slippery. If so, fit the Floorplate supplied
Why does Dorgard X
• Check that the Plunger is depressed.
2
• Check Dorgard X
has been Linked
• Check that the Battery Compartment is closed, the Batteries are correctly installed and
are of sufficient power in both Dorgard X
• Check that Dorgard X
movement of 10-15mm is ideal for the Plunger to lock down properly
• Check that Dorgard X
2
• Check Dorgard X
has not failed-to-safe. Is the unit beeping? (see Error Messages, Beeps
and Flashes on Page 23)
• Remove Batteries and wait 10 seconds before reinserting them in the Dorgard X
the unit
2
not retain the door in an open position?
2
and System X
2
is not fitted too low or high on the door. A vertical Plunger
2
is fitted to the side of the door that closes into the door frame
21
2
to reset