Standard Floorplate

IMPORTANT: Fit Dorgard X
Floorplate.
Warning! Before drilling holes or fastening Screws
into the floor, check the location of water pipes,
electrical cables, gas pipes etc. Failure to do so could
cause disruption to the building's services and may
result in serious injury or death.
1. Open the fire door to 90 degrees or to the desired open
position greater than 65 degrees. Slide the Floorplate under
the fire door with the Bump Stop part positioned behind
the door and as close to an adjacent wall as possible to
avoid tripping hazards.
2. Depress the Plunger on Dorgard X
in the recess of the Floorplate.
3. Slide/swivel the Floorplate so that the Bump Stop comes
into contact with the back of the door, ensure that the
Ferrule is still sitting centrally in the recess of the
Floorplate.
4. Mark the position of the Floorplates holes on to the floor
surface. When fitting to carpeted floors, trim around the
hole position to prevent the carpet pile being pulled by the
spinning drill bit or Screw.
5. Remove the Floorplate.
6. If the floor is concrete, drill 4 x 6mm holes (approximately
40mm deep) at the positions marked and insert the Rawl
Plugs supplied.
7. Position the Floorplate over the Rawl Plugs or marked
points and fasten the Floorplate to the floor using the black
Screws supplied.
8. Open the fire door against the Bump Stop and depress the
Plunger. If you have positioned the Floorplate correctly the
Ferrule should fit neatly into the recess of the Floorplate. If
not go back to step 3 and reposition the Floorplate.
Note. Fitting the Standard Floorplate may inhibit
2
Dorgard X
'push away to release' function. If this
function is required allow space from the back of the
fire door and the front of the Bump Stop, or fit the
Flat Floorplate.
2
to a door before fitting
2
so that the Ferrule sits