Page 1
PNOZ mc7p Configurable Control System PNOZmulti Operating Manual-1003050-EN-01...
Page 2
Preface This document is a translation of the original document. All rights to this documentation are reserved by Pilz GmbH & Co. KG. Copies may be made for internal purposes. Suggestions and comments for improving this documentation will be gratefully received.
Connecting the base unit and expansion modules Section 6 Commissioning General wiring guidelines Interface assignment Download modified project to the PNOZmulti safety system Connection example Section 7 Operation Messages Section 8 Technical Details Section 9 Order reference Operating Manual PNOZ mc7p 1003050-EN-01...
Introduction Introduction Validity of documentation This documentation is valid for the product PNOZ mc7p. It is valid until new documentation is published. This operating manual explains the function and operation, describes the installation and provides guidelines on how to connect the product.
24 - 127 are used they have different properties (see document entitled "Communication Interfaces"). Max. 1 PNOZ mc7p can be connected to the base unit Please refer to the document "PNOZmulti System Expansion" for the PNOZmulti base units that can be connected...
Safety Safety Intended use The fieldbus module PNOZ mc7p is an expansion module of the configurable control sys- tem PNOZmulti. It is used for communication between the configurable control system PNOZmulti and the CC-Link . CC-Link is designed for fast data exchange at field level. The expansion module CC-Link is a passive subscriber (Slave) in CC-Link.
All necessary documentation can be found on the PNOZmulti Configurator CD. Do not open the housing or make any unauthorised modifications. Please make sure you shut down the supply voltage when performing maintenance work (e.g. exchanging contactors). Operating Manual PNOZ mc7p 1003050-EN-01...
PNOZmulti Configurator. The base unit and the fieldbus module PNOZ mc7p are connected via a jumper. The fieldbus module is also supplied with voltage via this jumper. After the supply voltage is switched on or the control system PNOZmulti is reset, the fieldbus module PNOZ mc7p is configured and started automatically.
(0.88") Connecting the base unit and expansion modules You can install a maximum of 1 PNOZ mc7p to the left of the base unit. Do not connect a terminator to the last expansion module on the left-hand side. Install the expansion module in the position in which it is configured in the PNOZmulti Configurator.
It is possible to define which outputs on the safety system will communicate with CC-Link. The connection to CC-Link is made via a 5-pin screw connector. FG/PE DB DG SLD 1: DA (Channel A) 2: DB (Channel B) 3: DG (Earth) 4: SLD (Cable shield) 5: FG/PE (Functional earth) Operating Manual PNOZ mc7p 1003050-EN-01...
For the commissioning and after every program change, you must check whether the safety devices are functioning correctly. Connection example CC-Link CC-Link Slave n CC-Link Slave 1 Slave 3 CC-Link Master PNOZ mc7p CC-Link BAUD RATE CC-Link PNOZ mc7p Slave 2 ERR. Operating Manual PNOZ mc7p 1003050-EN-01...
When the supply voltage is switched on, the PNOZmulti safety system copies the configu- ration from the chip card. The LEDs "POWER","DIAG", "FAULT", "IFAULT" and "OFAULT" light up on the base unit. The expansion module PNOZ mc7p is configured and started automatically. Messages Legend:...
Vibration In accordance with the standard EN 60068-2-6 Frequency 10,0 - 150,0 Hz Acceleration Shock stress In accordance with the standard EN 60068-2-27 Acceleration Duration 11 ms Max. operating height above sea level 2000 m Operating Manual PNOZ mc7p 1003050-EN-01...
Page 16
35 x 7,5 EN 50022 Recess width 27 mm Material Bottom PPO UL 94 V0 Front ABS UL 94 V0 Dimensions Height 94,0 mm Width 22,5 mm Depth 122,0 mm Weight 110 g The standards current on 2012-03 apply. Operating Manual PNOZ mc7p 1003050-EN-01...
Order reference Order reference Product type Features Order no. PNOZ mc7p Fieldbus module, CC-Link 773 716 Order reference: Terminator, jumper Product type Features Order no. PNOZmulti bus terminator Terminator 779 110 KOP-XE Jumper 774 639 Operating Manual PNOZ mc7p 1003050-EN-01...
Need help?
Do you have a question about the PNOZ mc7p and is the answer not in the manual?
Questions and answers