MAGUIRE Gravimetric Gateway LineMaster Installation Operation & Maintenance page 67

Extrusion control & yield control
Table of Contents

Advertisement

Maguire Products, Inc.
LineMaster
Keypad Entry
Keypad adjustments are made using the keypad button located above the up
and down arrows on the keypad. Pressing the keypad button, will display:
ENTER TARGET _ _ _ _ _.
Enter the value of grams per length (g/l) using all 5 digits (the last digit is in
10ths). Be sure to include any leading zeros (example: 120.0 grams per length
(g/l) would be entered as 01200.) Keypad entries can only be entered in the
locked mode. For more information about the use of this key see Standalone
Operation and your specific application, XC-1 or XC-2.
Incremental Adjustments
Incremental adjustments are made using the up and down arrows on the keypad
of the LineMaster (XCC) Controller. Press and release once of the arrow keys
increments up or down by one tenth of a gram. Pressing and holding of the
arrow keys will rapidly increase or decease the value. Incremental entries can
only be made in the locked mode.
Lock Options
On the LineMaster (XCC) Controller keypad, between the up and down
arrows, is a LOCK key. This LOCK key can be used to Lock throughput,
overriding the LineMaster Extruder Speed Control MANUAL / LOCK switch. To
use the keypad LOCK option, the LTP parameter in the LineMaster (XCC)
Controller must be set to LTP 1xxxx, where the first digit in this parameter is set
to a 1. Setting the LTP parameter to use this option will de-activate (and ignore)
the LineMaster Extruder Speed Control MANUAL / LOCK switch.
For more information about the use of these keys see Standalone
Operation and your specific application, XC-1 or XC-2.