LineMaster
Controller - Right Side
SILENCE ALARM
POWER SWITCH
MIXER MOTOR FUSE
SILENCE ALARM
This button stops the STROBE and BEEPER ALARMS, but does not remedy the
cause of the alarm.
STROBE LIGHT and BEEPER ALARMS
The Strobe light flashes and the Beeper sounds when a
component fails to meter properly. Alarms begin after a
number of retries have occurred, this number
determined by the parameter table (see Parameters,
_AL). These alarms can also indicate an out-of-range
TARE weight. This range is set by the TL and TH
parameters; above 100 or below -50 grams.
POWER ON switch
Controls all power to the controller and all outputs. When power is switched off,
battery backed-up RAM preserves all internal totals and parameters. All other
functions are reset for normal start-up when power is restored.
PANEL FUSE for processor - 1/2 amp
Fuses power to the circuit board power supply, which includes the solenoid output.
FILL VALVE OPEN/CLOSE Switch
This switch opens or closes the Fill Valve above the LIW Hopper. This switch
is used to manually control the Fill Valve during maintenance or emptying of
the LIW Hopper.
Maguire Products, Inc.
STROBE
ALARM
LIGHT
SPEAKER
64