14
6.4. THE PROCEDURE FOR REPLACING CARBON AND MINERALIZATION
POST-FILTERS
1.
Turn off the feed valve 7 on the system, turn the tank valve 8 to the "Closed" position.
2.
Open the purified water faucet 5 to relieve permeate pressure.
3.
Disconnect the tubes that connect the carbon post filter and
mineralization filter to the rest of the system.
4.
Remove the used carbon post-filter and mineralization filter from
clip brackets.
5.
Install new carbon post-filter and mineralization filter.
6.
Connect the tubes to the new carbon post filter and mineralization filter to connect it to the system.
7.
Open feed valve 7. Open tank valve 8.
8.
Once the tank is full (you will hear the water stop flowing), drain all water from the tank into the sink by opening
faucet 5. When the water stops running, close the purified water faucet 5 so that the tank starts to re-fill. Filling
of the tank may take about 1 hour. Purified water can be slightly turbid after installation. Drain several additional
tanks of purified water. The water can be used now.

7. SANITIZATION OF REVERSE OSMOSIS FILTER

Sanitization of the reverse osmosis filter is recommended after it has been in use for an extended period
(~ 6 months), and when the filter is not going to be used for 3 or more weeks at a time. It is also desirable
to sanitize the system when replacing cartridges.
Using chlorine disinfectant tablets is recommended for reverse osmosis filter sanitization.
1.
Turn off the feed valve 7 on the system, turn the tank valve 8 to the "Closed" position.
2.
Remove and discard the pre-filter cartridges, carbon
post-filter and mineralization filter.
3.
Unscrew cap of membrane housing and remove
membrane using needlenose pliers if necessary. Put
the membrane into a tight bag and store in refrigerator
at +2...+5°C (36...41 oF).