Sanitization Of Pressure Tank - Ecosoft SENSE Installer And User Manual

Reverse osmosis filter
Table of Contents

Advertisement

Available languages

Available languages

  • ENGLISH, page 1
INSTALLATION AND OPERATION GUIDELINES FOR REVERSE OSMOSIS FILTER ECOSOFT SENSE
4.
Screw back on the second and the third pre-filter housings, screw on membrane housing cap, and connect the
tube from the faucet directly to the union tee without carbon post-filter.
5.
Put a chlorine tablet in the first housings. Fill the housings with water and
screw on.
6.
After 15 minutes, open the drinking water faucet 5 and feed valve 7.
7.
When water running from the faucet 5 starts to smell like chlorine, close both the faucet 5 and feed valve 7.
8.
Leave the system for 2-3 hours.
9.
Open the faucet 5 and feed valve 7 and let water run until bleach odor is gone.
10.
Turn off the feed valve 7. Install all consumable parts back into the system. Open tank valve 8 and feed valve 7.
11.
Drain the tank and re-fill for at least two times (until chlorine odor cannot be smelt).

7.1. SANITIZATION OF PRESSURE TANK

1.
Turn off feed valve 7.
2.
Open the faucet 5 and empty the pressure tank in the drain.
3.
Shut tank valve 8.
4.
Extract pre-filter cartridges.
5.
Screw back on the second and the third pre-filter housings.
6.
Connect the outlet of the third housing with the tank through the pre-filters rinse valve.
7.
Put a chlorine tablet in the first housings. Fill the housings with water and screw on.
8.
After 15 minutes, open tank valve 6.
9.
Open the feed valve 7 for 5 minutes.
10.
Close the tank valve 8 and leave the tank filled with chlorine solution for 1-2 hours.
Open tank valve 4and drain all water from the tank to the sink. Disconnect it from the third pre-filter and restore
11.
the original tubing of the system.
12.
Put cartridges in sumps and install the sumps on their heads. Then, open tank valve 8 and feed valve 7.
13.
Drain the tank and re-fill for at least three times (until chlorine odor cannot be smelt).
This manual is the intellectual property of Ecosoft. Copying and reprinting is prohibited. © 2019