System
No.
Description
Cause
E50
01...99
System error
Unexpected hard- or soft-
ware event
E51
01...99
System error
Unexpected hard- or soft-
ware event
E52
01...99
System error
Unexpected hard- or soft-
ware event
Options
No.
Description
Cause
E60
00
Relaisprint 0
Option print has been removed,
redirected or is defective
10
Relaisprint 1
20
Radio print
30
Fire protection
print
Closing sequence control / Sluice
No.
Description
Cause
E70
xx
CAN-Bus-
CAN-Address xx existing
configuration
two times.
E71
01
CAN-Connection No CAN-Connection
Solution
Switch on/ off drive
Perform factory reset
Perform software update
Contact manufacturer
Switch on/ off drive
Perform factory reset
Perform software update
Contact manufacturer
Switch on/ off drive
Perform factory reset
Perform software update
Contact manufacturer
Solution
Check if option exists
Falls If defective:
Replace or remove from configuration
Note:
Deleting the error 60
see mounting instruction ECO ETS
(Chapter 13.7.1)
Solution
Define closing sequence or sluice roll
correctly.
Plug in, control or replace CAN-Cable
Control if all CAN-Participants are swit-
ched on
Testing time
Reaction
Permanetly
W or F or H
Permanetly
W or F or H
Permanetly
W or F or H
Testing time
Reaction
Permanently
W
W
W
A
Testing time
Reaction
Permanently
W
Permanently
W
33