Operating
No.
Description
Cause
E10
01
Fullteach
Parameter Ao, Rod, Invers
required
or dAxis changed
02
Minimum opening angle
not reached
E11
01
Halfteach
Parameter Vo changed
required
(Opening)
02
Halfteach
Parameter Vc or FSlam chan-
required
ged
(Closing)
E14
01
Locking /
Door leaf stucks in the locking /
Electronic lock
electronic lock.
02
Inverse-operation has no
locking or locking force Fch is
not adjusted
E15
01
Obstacle in ope-
Too many obstacles encounte-
ning direction
red in a row
02
Obstacle in
closing direction
E16
01
Temperature
Temperature on output range
has reached 81° C
02
Temperature on output range
has reached 91° C
Solution
Proceed Teach
Check locking / electronic lock
Proceed complete, unobstructed
opening cycle
Proceed complete, unobstructed
closing cycle
Check function of locking / electronic lock
Adjust/increase locking force
Check system
Remove obstacle
Move door leaf to target position
Observe the limits of use.
Testing time
Reaction
When changing
H
the drive configu-
ration
During the Teach
When changing
W
the ride parame-
ters
When opening
H
from close-
position
At the end of the
W
Teach
Permanently
H, A
Restart after
60 s
Permanently
A
Drive running
reduced
A
Drive stands
still
31