SETTINGS

DRIVE PARAMETERS

Parameter
Description
Vo
Velocity open (velocity open)
Vc
Velocity close (velocity close)
TOEx
Hold open time opening element inside / outside (time hold opening element inside/outside)
TKey
Hold open time Key (time hold opening element Key)
TDelay
Start-up delay (time delay lock)
FDelay
Relief force when unlocking (force delay), only works if TDelay is >0.
TLock
Door hold-up time (time press close)
FLock
Pressing force while locking (force lock), only works when TLock is >0.
FSlam
Slam function (force slam)
FWind
Obstacle detection optimised for external doors. (force wind)
Fo
Opening force (force open)
Fc
Closing force (force close)
Foh
Hold open force (force open hold)
Fch
Locking force (force close hold)
Ao
Opening angle of the door (angle open)
If the opening angle is changed in the OPEN mode, the operating mode must be changed to
HAND to close the door.
Rod
Linkage types (Rod)
Invers
Inverse-Application: In case of power failure / error, the door leaf is opened from any position
by spring force (if not locked). Position of the motor plug is reversed to the standard drive. The
electric lock / holding magnet must be connected in reverse to the standard drive (see wiring
diagram E4-0141-713).
dAxis
Distance between door hinge rotation axis and the drives mounting level (distance Axis). dAxis
is a guide value. Depending on the mounting situation, dAxis must be adapted accordingly.
Fos
Limitation of the opening force.
Must not be increased in Germany!
* Note: A new set-up process (Teach) is required.
26
automatically sets FLock and FDelay if they are 0
(PARAMETER)
Setting range
0...14 (5...50 °/s)
0...14 (5...0 °/s)
0...60 s
0...180 s
0,0...4,0 s
0,0...7,0 A
0,0...4,0 s
0,0...7,0 A
0...10
OFF
OPEN
CLOSE
BOTH
0...9
0...9
0...9
0,0...3,5 A
20...(190 °) Rod dep.
Standard arm pressing
STD - PH
Sliding rail pulling
SLI - PL
Sliding rail pushing
SLI - PH
Leaf mounting pushing
WIN - PH
Without linkage pushing
DIR - PH
Without linkage pulling
DIR - PL
OFF
ON
-8...+25 cm
Rod dep.
5...14 A
Default
6
4
3 s
5 s
0,2 s
OFF
0,5 s
2,0 A
OFF
OFF
4
4
0
0
95 °
*
STD - PH
*
OFF
*
0 / +8 cm
Rod dep.
*
5 A