ECO ETS – Assembly Buddy
ERROR CODES
FAILURE WITH ERROR NUMBER
Safety elements
No.
Description
E20
01
SER Test
02
E21
01
SES Test
02
E22
01
EMY Test
Power supply
No.
Description
E30
01
30 V Error
02
03
E31
01
24 V General
02
E32
01
24 V Safety
E33
01
24 V E - Lock
02
E34
01
24 V CAN
32
(DISPLAY)
Cause
Solution
SER Test signal unsuccessful
SER short against ground
Check wiring of sensor or bridge
SER too slow
SER reacts too slow
Check wiring of the sensor
Check for reverse polarity of test signal
SES Test signal unsuccessful
SES short agains ground
Check wiring of sensor or bridge
SES too slow
SES reacts too slow
Check wiring of the sensor
Check for reverse polarity of test signal
EMY input to 24V
Check EMY bridge
Check wiring on EMY
Cause
Solution
30 V too low
power failure
Motor overload
30 V too high
Check power supply
Error when switching on
Replace hardware
Error when switching on
Overload, short of the 24V-inputs
(exclusive electric lock, Safety Elements)
Overvoltage / Undervoltage
Overvoltage / Undervoltage
Overload, short of Safety Elements
Error
Überlast, Kurzschluss Elektroschloss
Overvoltage / Undervoltage
Early warning
Overvoltage / Undervoltage
Overvoltage / Undervoltage
Overload, short of external supply CAN
Testing time
Reaction
Before closing
A
Before opening
A
Permanently
H
Testing time
Reaction
Permanently
A
Permanently
A
Restart after
10 s.
Permanently
A
Restart after
10 s.
Permanently
A
Restart after
10 s.
Permanently
A
Restart after
10 s.