ECO ETS – Assembly Buddy
ERROR CODES
MISBEHAVIOUR WITH ERROR-NO
Drive
No.
Description
E1
03
Encoder
04
05
06
07
08
09
10
01
Motor power
E2
02
E3
01
Damping
02
E4
01
Reference
switch
02
03
E5
00
Power limitation
30
(DISPLAY)
Cause
Solution
Canal A + B lost
Check encoder connection
Check motor cable
Short of A + B
Rotation direction of the motor doesn't
Disruptions
Door is blocked
Motor wire plugged wrong
Check if the Jumper is on X106
No canal A
No canal B
No canal A + B
Short of A + B
Power too high
Check motor cable
Check if the Jumper is on X106
Power too low
Jumper missing
Test failed once
Set drive to operating mode HAND and
Test failed twice
Damping defective or opening
If not, replace hardware
beyond heart curve peak
If yes, check/correct friction of the door
Detected in open-position
Check the connection and switching point
Not detected in closed-position
Reference switch must be actuated in
Not detected in open-position
Overload of the control
Check/correct friction of the door leaf and
Maximum power is limited
correspond with the linkage.
cauiously try if the door closes with
damping.
leaf and the closing spring preload.
of the refernece switch.
closed position (switching contact open).
the closing spring preload.
Testing time
Reaction
While driving
H
Before starting
Before starting
H
Before closing,
W
after starting up
Drive conti-
and then every
nues running,
24 hours.
buzzer active.
Open position
F
Before the first set
A
up ride
Permanently
A