  • Page 1 Temposonics ® Magnetostrictive Linear Position Sensors TempoLink Smart Assistant Operation Manual...
  • Page 2: Table Of Contents

    TempoLink Smart Assistant Operation Manual Table of contents 1. Introduction ..................................3 1.1 Purpose and use of this manual ............................3 1.2 Used symbols and warnings ............................3 2. Safety instructions ................................3 2.1 Intended use .................................3 2.2 Foreseeable misuse ...............................3 2.3 Installation, commissioning and operation........................4 2.4 Safety instructions for use in explosion-hazardous areas .....................4 2.5 Warranty ..................................4 2.6 Return ...................................4...
  • Page 3: Introduction

    1 and item 2 and only in conjunction with the third-party devices and components recommended or approved by MTS Sensors. As a prerequisite of proper and safe operation, the product requires correct transport, storage, mounting and commissioning and must be operated Do not step on the TempoLink smart assistant.
  • Page 4: Installation, Commissioning And Operation

    For diagnostic purposes, the TempoLink smart assistant 3. Connect the sensor and TempoLink smart assistant very can be returned to MTS Sensors or a repair facility explicitly carefully and pay attention to the polarity of connections authorized by MTS Sensors. Any shipment cost is the and power supply.
  • Page 5: Identification

    TempoLink Smart Assistant Operation Manual 3. Identification 4. Package content TempoLink smart assistant a Type L TempoLink smart assistant kit b Power supply 1 Plug-in power supply with plug adapters (AU, CCC, EU, UK, US) 2 Cable for insertion in existing sensor power supply with sensor mating connector and barrel connector Plug-in power supply with plug adapters or cable for 3 Barrel connector with pig-tail for connection to an existing...
  • Page 6: Connection Of Tempolink Smart Assistant To R-Series V Sensor

    TempoLink Smart Assistant Operation Manual AS00 (sensor – cable)* 6. Connection of TempoLink smart assistant to power supply There are two ways: 6.1 Using the plug-in power supply with plug adapters USB cable for optional connection of TempoLink smart Connect the barrel connector to the “INPUT 24 VDC”...
  • Page 7: Connection Of Tempolink Smart Assistant To Smartphone, Tablet Or Computer

    TempoLink Smart Assistant Operation Manual 7. Connection of TempoLink smart assistant to USB connector smartphone, tablet or computer Connect to a smartphone, tablet or computer to display the graphical user interface of the TempoLink smart assistant. 7.1 Connecting a Wi-Fi enabled device to the integrated Wi-Fi access point Activate Wi-Fi on the device and choose the network “TempoLink_xxxx”...
  • Page 8: Graphical User Interface

    TempoLink smart assistant. Firmware Update Firmware updates of the TempoLink smart assistant are available for download from the MTS Sensors website www.mtssensors.com. The firmware update is a zip file. Download the zip file, save it on your computer and unzip it.
  • Page 9: Menu Item Status

    TempoLink Smart Assistant Operation Manual 9.2 Menu item status values from metric units to imperial units. To do this, click on the black pencil in this line. The “Change Display Units” The status menu includes current information about the window opens. Select the desired unit and confirm by sensor status (Fig.
  • Page 10: Menu Item Parameters

    TempoLink Smart Assistant Operation Manual reset has been carried out, click the button EXIT COMMAND The Sensor Info menu includes information about the MODE. The “Exit Command Mode” window for exiting the connected sensor like stroke length, serial number and order command mode will open.
  • Page 11: Leds Of Tempolink Smart Assistant

    TempoLink Smart Assistant Operation Manual 10. LEDs of TempoLink smart assistant Three LEDs in the lid of the TempoLink smart assistant display the current status of the tool: TempoLink smart assistant LEDs Status LEDs LED A Communication between TempoLink smart assistant and sensor LED color Information Data transfer between TempoLink smart...
  • Page 12 MTS, Temposonics and Level Plus are registered trademarks of MTS Systems Corporation in the United States; MTS SENSORS and the MTS SENSORS logo are trademarks of MTS Systems Corporation within the United States. These trademarks may be protected in other countries. All other trademarks are the property of their respective owners. Copyright © 2020 MTS Systems Corporation. No license of any intellectual property rights is granted.