MAP 04
A A
G H
1 1
4 4
Feature Error MAP
PAGE 15 OF 15
069
Exchange the selector pen.
Verify for correct operation.
Is the problem still present?
I
:70
I
End of call.
071
Exchange
01 A/ A 1 G02,
E02,
F02
(D)
or
01 A/ A 1 F2, G2 (M).
Verify for correct operation.
072
(Entry Point
GI
Use Diagram at Figure 4-13 and 4-14 to isolate
problem.
01A/A1H2J5 connects to 01A/A1G2J5 (D) or
01 A/ A 1 F2J5 (M). Alarm should sound when G2J5
(D) or F2J5 (M) is grounded (+-2 sec).
Verify
audible alarm control setting if alarm does not
sound.
Exchange 01 A/ A 1 G2 (D) or 01 A/ A 1 F2 (M) card or
audible
alarm
assembly
01e/DS1
to
correct
problem.
(Entry Point
HI
Use
diagram
at
4-14
to
isolate
problem.
01 A/ A 1 H2G3 is ground when the security key is
off (removed).
01 A/ A 1 H2J4 is ground when the
security key feature is present.
End of call.
SY27·2510-6