038
MAP 02
Display MAP
PAGE
7 OF 19
Reconnect coax signal cable, feature card(s).
Verify correct operation.
039
Switch unit off.
Remove socket from CRT.
Exchange fuse.
Switch Unit On.
Does fuse fail again?
N
040
Exchange CRT. Do alignment procedure,
Reconnect coax signal cable, feature card(s).
Verify correct operation.
041
Test for short in cable from Low Voltage power
supply to CRT socket (Remove plug J2 from Low
Voltage power supply and test for short between
pins 1 and 14 at the CRT socket).
Repair or
exchange as needed.
Reconnect coax Signal cable, feature card(s).
Verify correct operation.