IBM 3278 Series Maintenance Information page 31

Display station
Hide thumbs Also See for 3278 Series:
Table of Contents

Advertisement

A B D
1 1 2
MAP 01
Terminal Failure MAP
PAGE
3 OF 13
011
Go To Map 02, Entry Point A.
012
Go To Map 05, Entry Point A.
013
Is light 3 above power ON/OFF switch on? (If
very dim use N path.) See Fig 4-1, 2 for
location)
N
014
Verify that the power on switch is on, line power
cable plugged in an active outlet and seated at
the primary power box.
Are above conditions correct?
I
~!~
.nd ve,",
·016
Switch unit off.
Verify Fuse F1 in main power box (Figure 4--3).
Did fuse fail?
N
017
Verify low voltage supply fuses (F2, F3, F5,
F6).
(See fuse locator Figure 4--11).
Are all fuses good?
1 1
1 054
E F G H
SY27·2510-6
(1/81)
2·01·3