IBM 3278 Series Maintenance Information page 35

Display station
Hide thumbs Also See for 3278 Series:
Table of Contents

Advertisement

MAP 01
Terminal Failure MAP
PAGE
7 OF 13
030
Switch power off.
Exchange analog card 01
AI
A 1 H2.
Switch unit on.
Adjust as required (see 5.2).
Test for proper operation.
031
Is the -44 volts incorrect?
N
032
Switch unit off.
Disconnect keyboard cable at 01
AI
A 1 G5 (D) or
01A/A1F5 (M).
Switch power on.
Verify failing voltage.
Is voltage still incorrect?
N
033
Replace keyboard logic card and
lor
keyboard
cable
I
cables as required.
Reinsert analog card in 01
AI
A 1 H2.
Switch power on.
Test
for
proper
operation.
Return
to
customer.
034
Switch power off.
Remove all logic cards.
Switch unit on.
Is voltage still incorrect?
888
R S T
SY27·2510-6
(1/81)
2-01·7