3 | Keysight | E4982A LCR Meter 1 MHz to 300 MHz/500 MHz/1 GHz/3 GHz - Coniguration Guide
Step 3. Choose accessory option for using test ixture (if not required, go to Step 4.)
Description
Working standard set
Test head extension
cable set
16195B calibration kit
Test ixture stand
3.5 mm-to-7 mm
coaxial adapter
Note: Refer to Upgrade for retroit information on the above options.
Step 4. Choose general/miscellaneous accessory option (If not required, go to Step 5.)
Description
Keyboard
Mouse
Rackmount kit
Front handle kit
Handle/rack mount kit
Note: Refer to Upgrade for retroit information on the above options.
Step 5. Choose data storage
Description
Standard data storage
Step 6. Choose calibration certiicate option
Description
ISO 17025 compliant calibration
ANSI Z540 compliant calibration
Option No.
Requires
E4982A-004
None
E4982A-020
None
E4982A-710,
E4982A-700
-720
E4982A-700,
E4982A-710
-720
E4982A-700,
E4982A-720
-710
Option No.
Requires
E4982A-810
None
E4982A-820
None
E4982A-1CM
None
E4982A-1CN
None
E4982A-1CP
None
Product No.
Requires
E4982A-019
None
Option No.
E4982A-1A7
E4982A-A6J
Not Compatible
Additional Information
None
Needed when performing calibration at DUT contacts of
custom ixture or component handler. (Not required when
using the Keysight Technologies, Inc. RF component
test ixtures). Includes Shorting Bars and 51.0 Ω Chip
Resistors (SMD size: 1.0 x 0.5 mm, 1.6 x 0.8 mm, 2.0 x 1.2
mm, 3.2 x 1.6 mm).
None
Coaxial cable set for extending the test head cable to 2 m
from standard 1 m. Required when 2 m test head cables
are needed for installation.
None
Required for performing calibration at 7 mm connector
plane of 3.5 mm-to-7 mm adapter attached to 3.5 mm
test port connector on test head. Includes OPEN, SHORT,
50 Ω LOAD, LOW-LOSS CAPACITOR standards and
carrying case. Usable for multiple E4982As.
Required for using Keysight's RF component test ixtures
None
and the 16195B calibration kit. See Available Accessories
in this guide.
Required for using Keysight's RF component test ixtures
None
and the 16195B calibration kit. See Available Accessories
in this guide.
Not Compatible
Additional Information
None
USB Keyboard for simplifying measurement setup and
programming.
None
USB Mouse for simplifying measurement setup and
programming.
None
Not installable simultaneously with
E4982A-1CP.
None
Not installable simultaneously with
E4982A-1CP.
None
Not installable simultaneously with
E4982A-1CM or 1CN.
Not Compatible
Additional Information
None
Option 019 is the only data storage option for the
E4982A. Must choose this option.
Additional Information
ISO 17025 compliant calibration
ANSI Z540 compliant calibration