3.5 Gun is activated
Gun is open - Control piston is closed. Micro switch is deactivated. Motor
starts.
Non return valve
Outlet
3 BAR
3.6 Machine run
Machine runs (normal working pressure). Gun is open.
Non return valve
Outlet
98BAR
Operation.
Pump
3 BAR
Inlet
Pump
100 BAR
3 BAR
Inlet