5.2 Tools and materials
Make sure you have all the tools and materials you will need for the installation at hand to work in total safety and compliance with the
current standards and regulations. The following figure illustrates the minimum equipment needed by the installer.
5.3 Cable list and minimum thickness
Connections
Control panel power supply 230V
Flashing light 24V
Photocell transmitters
Photocell receivers
24V Accessories power supply
Command buttons
Endstop
Encoder plug
Antenna connection
N.B.: If the cable length diff ers from that specifi ed in the table, then you must determine the proper cable diameter in the basis of the
actual power draw by the connected devices and depending on the standards specifi ed in CEI EN 60204-1.
For connections that require several, sequential loads, the sizes given on the table must be re-evaluated based on actual power draw and
distances.

5.4 Standard installation

3
2
7
230 V
3 x 1,5
2 x 1,5
4 x 1
*
4 x 1 - RX
4
Wiring for microswitches:
*
5 x 1mm
Power wires to motor:
2 x 1,5 mm
2
up to 20 m;
2
2 x 2,5 mm
up to 30 m.
Type of cable
FROR CEI
20-22
CEI EN
50267-2-1
2402C 22AWG
RG58
6
4
1
8
2
Length of cable
Length of cable
1 < 10 m
2
3G x 1,5 mm
3G x 2,5 mm
2
2 x 0,5 mm
2
2 x 0,5 mm
2
4 x 0,5 mm
2
2 x 0,5 mm
2
2 x 0,5 mm
2
3 x 0,5 mm
max. 30 m
max. 50 m
4
1) Operator
2) Control panel
3) Radio receiver
4) Photocells
Length of cable
10 < 20 m
20 < 30 m
2
3G x 4 mm
2
2 x 1 mm
2 x 1,5 mm
2
2 x 0.5 mm
2 x 0,5 mm
2
4 x 0,5 mm
4 x 0,5 mm
2
2 x 0,5 mm
2 x 1 mm
2
2 x 0,5 mm
2 x 0,5 mm
2
3 x 1 mm
3 x 1,5 mm
4
5
3 x 1
2 x 1
*
2 x 1 - TX
1
5) Selector switch
6) Antenna
7) Flashing light
8) Transmitter
2
2
2
2
2
2
2