Husqvarna LG 504 Operator's Manual

Husqvarna LG 504 Operator's Manual

Hide thumbs Also See for LG 504:
Table of Contents

Advertisement

LG 504
EN
Operator's manual
2-23

Advertisement

Table of Contents
loading

Summary of Contents for Husqvarna LG 504

  • Page 1 LG 504 Operator's manual 2-23...
  • Page 2 Contents Introduction..............2 Transportation, storage and disposal......19 Safety................5 Technical data.............. 20 Operation..............10 EC Declaration of Conformity........23 Maintenance..............13 Introduction California Proposition 65 WARNING The engine exhaust from this product contains chemicals known to the State of California to cause cancer, birth defects or other reproductive harm.
  • Page 3 Product overview 1. Operator's manual 16. Hour meter and indicators for battery charge and engine oil pressure 2. Handle 17. Ignition key 3. Throttle control 18. V-belt 4. Hydraulic oil tank 19. V-belt cover 5. Hydraulic oil dipstick 6. Breather filter 7.
  • Page 4 Symbols on the product EPA (US Environmental Protection Agency) throttle control Be careful and use the product correctly. This product can cause serious injury or death to the operator or others. Read the manual carefully and make sure that you understand the instructions before you use the product.
  • Page 5 Move the product rear- ward. Hour meter. Engine oil pressure. Note: Other symbols/decals on the product refer to special certification requirements for some markets. Risk of injury. Be careful around the drive belt. Type plate Risk of injury if the handle falls on you. Lock the handle in the lifted position.
  • Page 6 General safety instructions • Make sure that only approved persons are in the work area. • Keep the work area clean and bright. • Make sure that you are in a safe and stable position WARNING: Read the warning instructions during operation.
  • Page 7 loss of strength, changes in skin color or • The exhaust fumes from the engine contain carbon condition. monoxide which is an odourless, poisonous and very dangerous gas. To breathe carbon monoxide can • Symptoms can increase in cold temperatures. Use cause death.
  • Page 8 Make sure that the vibration damping units are • Do a check of the safety devices regularly. If the correctly installed. safety devices are defective, speak to your Husqvarna service agent. • Examine the vibration damping units for damages and wear. Muffler •...
  • Page 9 If the battery that follow before you use the product. has a deformation or is damaged, speak to an approved Husqvarna service agent. • If the maintenance is not done correctly and regularly, the risk of injury and damage to the product increases.
  • Page 10 Operation Introduction 1. Pull the lever for the decompression valve to the start position (A). WARNING: Read and understand the safety chapter before you use the product. To do before you operate the product • Read the operator's manual carefully and make sure that you understand the instructions.
  • Page 11 3. Turn the start handle until the engine starts. a) For products with a throttle control that is not EPA: b) For products with EPA throttle control: Pull the 4. Let the engine operate at idle speed for 2–3 minutes. position stop (A) up, and move the throttle control to idle speed (B).
  • Page 12 a) When the engine starts, immediately release the b) For products with EPA throttle control: Pull the ignition key. The ignition key goes back to position stop (A) up, and move the throttle control position (A). to idle speed (B). Make sure that the throttle control locks in the position.
  • Page 13 a) Turn the ignition key to the stop position (A). CAUTION: Do not operate the product when the LED indicator (D) is on with a constant red light. This causes wear to the product. • E: Red or green. Power supply indicator. When you turn the ignition key, a calibration of the compaction indicator starts.
  • Page 14 General product maintenance Each 6 Before use, Yearly, each Each 100 h months or each 10 h 500 h 250 h Clean the product. Make sure that nuts and screws are tightened. Examine the throttle control and the forward and reverse control for damage.
  • Page 15 Engine maintenance Before use, After the Yearly, each Each 250 h each 10 h first 20 h 500 h Drain water from the fuel system. Replace the fuel filter. To clean the product 1. Examine the air filter indicator. CAUTION: Before you clean the product, attach a plastic bag tightly around the fuel tank cap.
  • Page 16 2. Turn the locking knob on the air filter 3. Examine the V-belt for damages and wear. Replace counterclockwise and remove the air filter (A) from the V-belt if it is necessary. the air filter housing. 3. Clean the air filter housing with a brush. 4.
  • Page 17 Use a voltage-regulated battery charger for gel Recommended battery chargers batteries. Refer to on page 17 . Speak to your Husqvarna dealer for more information about the correct battery charger. • If the battery is not used for a long period of time, charge it fully before you use it.
  • Page 18 To do a check of the hydraulic oil level Battery charger type Recommendations 1. Remove the dipstick from the hydraulic oil tank. Float charger. 13.2–13.8 V. Max. 1 A. No time limit at lower voltag- Fast charger, constant Max. 15.6 V. No current voltage charger.
  • Page 19 5. Fill with hydraulic oil of the correct type. Refer to 6. Put the dipstick into the hydraulic oil tank. Technical data on page 20 . Transportation, storage and disposal Transportation 2. Attach the lifting equipment to the lifting eye. WARNING: Be careful during transportation.
  • Page 20 Disposal • Do not discard the battery as domestic waste. • Send the battery to a Husqvarna service agent or • Chemicals can be dangerous and must not be discard it at a disposal location for used batteries. discarded on the ground. Always discard used chemicals at a service center or an applicable disposal location.
  • Page 21 Manual start Electrical start EPA, electrical start Battery type Spiralcell technology Spiralcell technology AGM battery AGM battery Battery voltage, V 12V/48Ah 12V/48Ah Starter motor 12V/2.0 kW 12V/2.0 kW * = For further information and questions about this specific engine, refer to the engine manual or the web site of the engine manufacturer.
  • Page 22 Product dimensions Handle height, operation Length with handle folded, 1190/46.9 1025/40.4 position, mm/in. mm/in. Handle height, transport Length including handle, 1320/52 1670/65.7 position, mm/in. mm/in. Bottom plate contact area Width without extensions, without extensions, m /sq. 0.21/2.26 mm/in. 550/21.7 Length bottom plate, Width including 2x75 mm 700/27.6 mm/in.
  • Page 23 EC Declaration of Conformity EC Declaration of Conformity We, Husqvarna AB, SE-561 82 Huskvarna, Sweden, tel: +46-36-146500, declare on our sole responsibility that the product: Description Reversible Plate Compaction Machine Brand Husqvarna Type/Model LG 504 Identification Serial numbers dating from 2019 and onwards...
  • Page 24 www.husqvarnacp.com Original instructions 1140392-26 2020-04-06...

Table of Contents