Install Water Outlet Hose; Install Water Inlet Tube; Install Oil Pressure Tube; Install Plate With Pressure Actuator - Toyota pmn Installation Instructions Manual

Lhd/rhd turbo kit
Table of Contents

Advertisement

44
K
K
K
K
K
R
K
R
R

5. INSTALL WATER OUTLET HOSE.

(a) Install the outlet hose onto the outlet adapter.
K: Water outlet hose (17-1)
Torque: 14 Nm
NOTICE: Ensure that the connection is pointing
into the right direction (in line with
exhaust manifold connection)

6. INSTALL WATER INLET TUBE.

(a) Install the water inlet tube onto the water inlet adapter.
K: Water inlet tube (16-1)
Torque: 12 Nm
NOTICE: Ensure that the water inlet tube is
pointing into the right direction.

7. INSTALL OIL PRESSURE TUBE.

(a) Install the oil pressure tube with the screw and 2
copper seal rings.
K: Oil pressure tube (13-1)
K: Screw (13-2)
K: Copper seal rings (2 pcs.) (13-3)
90˚
Torque: 25 Nm
NOTICE: Ensure that the connection is pointing
into the right direction (in line with turbo
inlet housing)

8. INSTALL PLATE WITH PRESSURE ACTUATOR.

(a) Install the pressure actuator with bracket, with the 2
bolts and clip.
R: Pressure actuator
R: Bolt (2 pcs.)
R: Clip
Torque: 10 Nm
R

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mr 21zz-fte

Table of Contents