Operator Troubleshooting Guides - Frymaster Pasta Magic Installation And Operation Manual

Gas water cooker
Hide thumbs Also See for Pasta Magic:
Table of Contents

Advertisement

5.2

Operator Troubleshooting Guides

Problem
BURNERS DO NOT
LIGHT
(Main gas supply
valve verified to be
open, the gas valve is
verified to be ON, and
power switch is
verified to be ON.)
COOKPOT DID
NOT FILL WHEN
VALVE WAS
TURNED ON
(Water supply to unit
verified to be ON.)
Probable Causes
A. Ignition module lockout (the
burners failed to light within 4
minutes).
Indicator: Amber trouble light
on control panel is illuminated.
B. Stuck water level float switch.
(If the float switch does not indi-
cate sufficient water in the cook-
pot, it will not allow the burners
to fire.)
C. Failed power switch.
D. Failed ignition module or gas
valve, or broken or loose wiring.
A. Failed water valve.
Corrective Action
A. Turn the switch to the OFF po-
sition. Wait 60 seconds and
turn the power to the ON posi-
tion. Wait at least 4 minutes.
B. Remove the probe block cover
and clean the float switch with
a solution of detergent and
water.
deliming solution.
C. Call FAS.
C. Call FAS.
A. Call FAS.
5-2