4.4
Adjusting the Burner Gas Pressure
Frymaster recommends that ONLY qualified service personnel perform this task.
1. Ensure that the gas valve knob is in the OFF position.
2. Remove the pressure tap plug from the gas valve assembly.
3. Insert the fitting for a gas pressure-measuring device into the pressure tap hole
4. Place the gas valve in the ON position.
5. Place the power switch in the ON position. When the burner has lit and burned steadily for at
least one minute, compare the gas pressure reading to the pressure for the corresponding gas in
the appropriate table below.
DANGER
Pressure Tap Plug
Typical Valve Assembly
Burner Gas Pressure
Gas
Natural
Propane
4-4
Pressure
3" WC
.087 kPa
8.718 mbar
8.25" WC
2.05 kPa
20.55 mbar