6.4.6 Technician Troubleshooting Guides

TROUBLESHOOTING THE 24VAC POWER SUPPLY SYSTEM

Verify that the power cord is
properly connected to the
electrical service and that
the circuit breaker is not
tripped.
Place the master ON/
OFF switch in the ON
position.
Was there an
audible snap from the
contactor indicating the
coil energized?
No
Is 24VAC present
across Pins 1and 2
of the 15-pin connector
on the front of the
contactor box?
No
Is line voltage
present on the line side of
the transformer?
No
Check 5-amp transformer
fuse. Replace if blown. If fuse
is OK, cause is loose or broken
wiring, or the electrical service
circuit is dead.
The primary indicator of a
problem with the 24VAC
Power Supply System is a
failure of the computer to
activate when the master
ON/OFF switch is placed
in the ON position and the
computer ON/OFF switch
is pressed.
24VAC Power Supply
Yes
System is OK.
Causes are broken or loose wiring
or a failed contactor. If wiring and
Yes
connections are verified to be intact,
replace contactor.
Is 24VAC
Yes
present on the load side of
the transformer?
No
Transformer has
failed. Replace.
6-13
Verify continuity of
master ON/OFF switch in ON position.
Replace switch as required.
Yes
If switch is OK, causes are broken
or loose wiring. Check connections and
replace wiring as required.