Measuring Flame Current; Simmer Mode Adjustment - Frymaster Pasta Magic Installation And Operation Manual

Gas water cooker
Hide thumbs Also See for Pasta Magic:
Table of Contents

Advertisement

To adjust the burner gas pressure, remove the cap from the gas valve regulator and use a
6.
flat-tipped screwdriver to adjust the regulator to obtain the correct pressure.
7. Place the power switch and the gas valve in the OFF position. Remove the fitting from the pres-
sure tap hole and reinstall the pressure tap plug.
4.5

Measuring Flame Current

When the burner flame is properly adjusted, it will produce a current between 2.5 μA and 3.5 μA.
Flame current is measured by placing a microamp (not milliamp) meter in series with the white sens-
ing wire on one of the ignitors. This is accomplished as follows:
1. Place the power switch in the OFF position.
2. Disconnect the sensing wire from one of the burner ignitors and connect it to the positive lead of
the meter. Connect the negative lead of the meter to the terminal from which the sensing wire
was removed.
3. Place the power switch in the ON position to light the burners. After the cookpot temperature
0
0
reaches 190
F (88
the unit is to normal operation temperature, the more accurate the reading will be.
4.6

Simmer Mode Adjustment

NOTE: The simmer temperature is adjustable from 130
thermostat dial. It is set to 190
0
(88
C) for proper performance.
GAS VALVE REGULATOR CAP
C), wait at least one minute before checking the reading. NOTE: The closer
0
0
F (88
C) at the factory. It is recommended to keep it set to 190
°
°
F to 205
4-5
°
°
F (54
C to 96
C) using the
0
F