9.1.2. Sync

Sync
Input
Source
Clock
Rate
Output
These settings allow you to specify the inputs for receiving synchronization and tempo
signals, as well as the input and output clock rates. By changing these settings, you
determine which type of clocking signal will be transmitted via the output connectors and
which type will be recognized by the sync/clock inputs.
Auto Mode works as follows:
If no clock signal is received, you can set the tempo and press Play. The KeyStep
Pro will then behave as in Internal mode.
If Clock / MIDI Transport Control (MTC) is received, the external clock takes
priority over the internal clock. The resulting tempo is calculated based on the
external clock. When the external clock stops, the sequencers/arpeggiators stop.
If a MIDI Stop message is received, all running sequencers/arpeggiators will
stop.
The Sync Output submenu enables you to set the clock type for the analog output clock:
1PP16 = 1 pulse per 16th beat (clocked)
1PP8 = 1 pulse per 8th beat (1 pulse every two 1/16th beats)
1PPQ = 1 pulse per quarter beat
1PP2Q = 1 pulse per 2 quarter beats
1PP4Q = 1 pulse per 4 quarter beats
2PPQ = 2 pulses per quarter beat
24PPQ = 24 pulses per quarter beat
48PPQ = 48 pulses per quarter beat

9.1.3. Metronome

Metronome
Output
Count-in
Time
division
Time
signature
To use the Metronome, activate it with SHIFT + Tap Tempo/Metronome. The default time
signature is 4/4. For example, to set the time signature to 5/8, set Time division to 8 and Time
signature to 5.
Arturia - User Manual Keystep Pro - KeyStep Pro Configuration
Values
[Internal, USB, MIDI, Clock, Auto (d)]
[1 PP16, 2 PPQ, 24PPQ (d), 48PPQ]
[1 PP16, 2 PPQ8, 1 PPQ, 1PP2Q, 1 PPQ4Q,
2PPQ, 24PPQ (d), 48PPQ]
Values
Line, Speaker (d), Line Line/Speaker
OFF, 1 bar (d), 2 bars
1/4, 1/4 Triplets 1/8, 1/8 Triplets, 1/16 (d), 1/16
Triplets, 1/32, 1/32 Triplets
1-16, default 4
Description
Defines tempo and sync source
Allows you to choose from the different
analog clock rate types
Use these settings to sync KeyStep Pro to
various analog clock types
Description
Selects
the
output
metronome signal
Selects count-in duration when
starting Record
Set number of beats in a measure
Sets the number of beats that
make up a measure/bar
of
the
119