Hitachi C 12LSH Handling Instructions Manual page 84

Slide compound miter saw
Table of Contents

Advertisement

English
6.
Storage
After operation of the tool has been completed, check that the following has been
performed:
(1)
Trigger switch is in OFF position,
(2)
Power plug has been removed from the receptacle,
When the tool is not in use, keep it stored in a dry place out of the reach of children.
7.
Replacement of guard (Fig. 55)
After long-term use, the blade slot in the guard may widen
and require replacement. If the blade slot should widen,
replace the guard with a new one. After replacing, make a
groove on it. Refer to "1. Cutting a groove on the guard" on
page 62.
8.
Replacement of Poly-V-Belt (Fig. 56)
The power of the motor is transmitted to the saw blade by
a Poly-V-Belt. When the Poly-V-Belt is broken or damaged,
remove the belt cover by loosening the four 5 mm screws
(see Fig. 2 on page 56) and replace the damaged one with
the new one.
When connecting the belt on pulleys, fi rst connect 2 or
3 teeth of Poly-V-Belt to the grooves of the pulley (A)
and pulley (B). Then turning the pulley (A) and pulley (B),
connect all 13 teeth of the belt to the pulleys.
9.
Lubrication
Lubricate the following sliding surfaces once a month to
keep the power tool in good operating condition for a long
time (Fig. 1 on page 56 and Fig. 2 on page 56).
Use of machine oil is recommended.
Oil supply points:
* Rotary portion of hinge
* Rotary portion of vise assembly
* Rotary portion of holder (A)
10. Cleaning
Periodically remove chips, dust and other waste material from the surface of the power
tool, especially from the inside of the lower guard with a damp, soapy cloth. To avoid a
malfunction of the motor, protect it from contact with oil or water.
If the laser line becomes invisible due to chips and the like adhered onto the window of the
laser marker's light-emitting section, wipe and clean the window with a dry cloth or a soft
cloth moistened with soapy water, etc.
11.
Replacing supply cord
If the supply cord of Tool is damaged, the Tool must be returned to Hitachi Authorized
Service Center for the cord to be replaced.
84
Guard
Fig. 55
Pulley (A)
Poly-V-belt
Pulley (B)
Fig. 56

Advertisement