ZN‐S1000VE Installation Guide
3.2. Back Panel
Ain
DI
RS-232
1
1
2
Rx Tx
DC12V
Reset
1
1
2
C
Ethernet
USB
Aout
DO
RS-485
⑤ USB 2.0 port
Insert a USB storage device or Wi‐Fi devices. (Ralink RT73 or RT3070 chipset based wireless
device is available.)
⑥ LAN connector
Use the RJ45 LAN connector for 10/100 Base‐T Ethernet.
⑦ Audio IN/OUT
The encoder has one channel mono audio input/output. As the output power for the audio is
low, an amplifier speaker is needed.
⑧ DI/DO
The encoder supports two channels for each of DI and DO. Refer to the section
"4.1.Connectors" for more specific information.
⑨ RS‐232/RS‐485
RS‐232C Terminal Block is used for some devices such as POS terminal block. RS‐485 is used for
PTZ controls.
⑩ Reset
Reboot the device system or reset the device to its Factory default settings. Refer to the
section "5.3. Reset" for more specific information.
⑪ Power connector
Connect the power adaptor for power supply. DC 12V 1A adaptor is needed.
⑫ RS‐485 termination register switch
Select ON or OFF for RS‐485 termination register.
07A.05