WARNING ! ANY OTHER TYPE OF SERVICE OPERATION OR TEST, EXCEPTION MADE FOR THOSE SHOWN IN THE PRE-
PROBLEM
Not enough water flow on the brush
Not enough suction
The machine doesn't clean evenly
The motor fails to operate
Circuit breaker continue to trip
MIRAGE Reinigungstechnik
Alt Roggentiner Weg 11, D- 18196 Dummerstorf

TECHNICAL DIAGRAMS

TROUBLESHOOTING

SENT MANUAL, MUST BE CARRIED OUT BY AUTHORISED SERVICE CENTRES ONLY
1. Solution tank is empty
2. Tap is closed
3. Detergent solution filter clogged
4. Solution duct clogged between tank and brush.
5. Incorrect pump pressure setting
6. Vacuum pipe clogged or damaged
7. Vacuum motor not operating
8. Damaged gasket recovery tank cover
9. Brushes are worn
10. Elevated motor absorption has tripped the circuit breaker
11. The thermal problem of the brush gearmotor has tripped
12. Motor continues to short circuit
CAUSE
26
Telefon: 038208 82560 Fax: 038208 82561 Mobil: 0172 38033
SOLUTION
Fill the tank
Open the tap
Clean the filter
Make sure there is no incrustations
Set the pressure of the pump between 0.5 and
0.8 bar
Check and eventually replace the pipe
Have it checked
Replace it
Change the brushes
Reset the circuit breaker
Wait for the motor to cool and restart the
machine
Replace the motor
www.mirage-reinigungstechnik.de