To fit the Tynex brushes:
Position yourself behind the machine and press the handle downwards (1) and let the stand (2) lower down.
Remove the side panel and insert the brushes. Pay attention to the different shapes of the locking pins.
Close the side panel by inserting the cylindrical hollow side of the brushes into the proper pins. Fix the side panel by using the screws.
Use the two centring pins to position the side panel properly (3).
1
For using an external vacuum during the dry cleaning phase, proceed as follows:
• Connect the external vacuum (A) to the machine by using the mouthpiece;
• Remove the right side panel (B);
• Inside the machine, connect the hose C to mouthpiece 2;
• Close the side panel.
A
For using an internal vacuum during the dry cleaning phase:
• Remove the side panel by using the proper hook;
• Inside the machine, connect the hose A to mouthpiece 1;
• Inside the machine, connect the hose B to mouthpiece 2;
• Check that the bag (F) is present in the vacuum and close the side panel. Fit a bag if there isn't one.