Our escalator machine must be operated by properly trained authorised staff.
Escalator cleaners that do not operate properly must be taken out of service immediately.
CHECK BEFORE USE
Make sure to check the following before using the machine:
• Make sure the brushes are in good condition;
• If an internal vacuum is used, make sure that the bag is not full;
• Make sure that the rubber pieces of the brush head are in good condition.

POSITIONING THE MACHINE AND START UP

Connect the power cord to the mains;
Position the machine on the escalator landing plate and raise the stand (if it is still lowered);
Place the smaller side of the brush head (i.e. the side without the gear box) as close to the side of the escalator
as possible;
Activate the brake;
Turn on the vacuum and then the brushes;
Turn on the escalator and make sure it moves toward the machine.

ROTATING THE BRUSH HEAD

Unscrew the fixing knob (A) of the brush head;
Rotate the head and tighten the knob;
Position the machine on the side of the escalator that remains to be cleaned and repeat the previous operation;
At the end of operation remove any dust residues left on the landing plate using the vacuum wand accessory (optional for BASE version).