Primary Functions And Controls - Mirage EC52 User Manual

Escalator cleaner
Table of Contents

Advertisement

1. BRUSH SWITCH
By pressing the switch towards position 1, the brush
function starts.
By pressing the switch towards pos. 0 the brush stops
immediatly.
2. GREEN LIGHT SIGNALLING POWER IS ON
The green light indicates that the machine is power supplied.
WHEN THE LIGHT IS ON, IT IS FORBIDDEN TO OPEN THE ELECTRICAL
SWITCHBOARD OR CARRY OUT ANY MAINTENANCE OPERATION.
A
6. BRAKE
The lever enables the brake (A); it must be applied when the machi-
ne is used for cleaning the escalator.
MIRAGE Reinigungstechnik
Alt Roggentiner Weg 11, D- 18196 Dummerstorf

PRIMARY FUNCTIONS AND CONTROLS

3. VACUUM SWITCH
By pressing the switch towards pos. 1, the
vacuum unit comes on.
By pressing the switch towards pos. 0, the
vacuum unit switches off.
5. 5A RESETTABLE FUSE
If the absorption of the brush motor exceeds 5A for a certain amount of time,
the fuse triggers to protect the motor.
To enable this function again, press the RESET button from the dashboard.
Always check the brushes, before resetting the fuse.
7. KNOB ROTATING THE BRUSH HEAD
After cleaning one side of the escalator, use the knob (B) to rotate
the brush head in order to clean the opposite side.
12
Telefon: 038208 82560 Fax: 038208 82561 Mobil: 0172 38033 26
4. PUMP SWITCH
Press the switch to position 1 to turn the pump on.
Press the switch to position 0 to turn the pump off.
B
www.mirage-reinigungstechnik.de