OIT***-F113-B12-CB*
Commissioning
6.2

Programming

The OIT system is provided with default parameters see chapter 11.2. The
operating parameters from these default parameters are stored in a file on the
flash memory of the OIT. The operating parameters may be configured with the
help of OITControl.
The operating parameters of the OIT system can be imported using a Data Matrix
code that contains the required parameters. Use the Data Matrix code in the
appendix to reset the OIT system to its default settings: see chapter 11.2
Parameterizing the device with a Data Matrix code
Correctly configure the OIT system for your equipment as follows:
1. Supply power to the OIT system.
recently saved parameter file; or the default parameters. The LED "Ready" will
then flash for approx. 30 seconds.
2. Hold a Data Matrix code containing the new encoded operating parameters at
a defined distance in the field of the OIT system. Hold the Data Matrix code at
a distance of about 300 ... 350 mm in front of the OIT system.
operating parameters and is written into the parameter file. The "COK" LED
flashes for approx. 5 seconds. The OIT system will then restart. The "RDY"
LED will flash again for approx. 30 seconds. Make sure that there are no Data
Matrix codes in the image field when restarting the OIT system. Only then can
a connection to the OIT system be established.
Data Matrix code resistant to dirt
You can make the default Data Matrix code or any other code resistant to dirt by
sealing the code in a non-reflective film.
Note!
Network connections between OITControl and OIT system
After connecting the power, no network connection to the OIT system can be
established in the first 30 seconds. During this time, the OIT system can be
programmed with a Data Matrix code.
26
Once the OIT system has been powered, it loads the data from the most
Once the OIT system detects the code, the data is adopted as the new