Installing The Enclosures; Installation Checklist; Connecting Storage Enclosures; Cable Requirements For Storage Enclosures - Lenovo D1012 Hardware Installation And Maintenance Manual

Table of Contents

Advertisement

4

Installing the enclosures

Installation checklist

The following table outlines the steps required to install the enclosures, and initially configure and provision
the storage system. To ensure successful installation, perform the tasks in the order presented.
Table 9 Installation checklist
Step Task
1.
Install the Storage Enclosure in the rack, and
attach the enclosure bezel.
2.
Connect Storage Enclosure to the server's
RAID adapter.and optional Storage
Enclosures.
3.
Connect an optional Storage Enclosure to the
first Storage Enclosure as shown. Connect
additional optional Storage Enclosures in the
same fashion as appropriate.
4.
Connect power cords to each Storage
Enclosure.
5.
Test enclosure connectivity.
6.
Connect hosts.
1
See
Enclosure bezel attachment and removal
chassis.
NOTE: Additional installation notes:
• ESMs within the same enclosure must be of the same type.
• For optimal performance, do not mix 6 Gb and 3 Gb disk drives within the same enclosure.

Connecting Storage Enclosures

Lenovo Storage D1012/D1024 Storage Enclosures support these maximum configurations:
• Up to eight D1012 Storage Enclosures with12 3.5"drives for a maximum of 96 disk drives.
• Up to eight D1024 Storage Enclosures with 24 2.5" drives for a maximum of 192 drives.
A mix of SFF and LFF Storage Enclosures is supported.
D1012 and D1024 ESMs support both 3-Gbps and 6-Gbps internal disk drive speeds together with 3-Gbps
and 6-Gbps expander link speeds.
CAUTION: Some 6-Gbps disks might not consistently support a 6-Gbps transfer rate. If this happens, the
system automatically adjusts transfers to those disks to 3 Gbps, increasing reliability and reducing error
messages with little impact on system performance.

Cable requirements for storage enclosures

Use only Lenovo Storage or OEM-qualified cables, and observe the following guidelines:
• When installing SAS cables to Storage Enclosures, use only supported mini-SAS cables.
1
2
on page 18 for more information about installing enclosure bezels to 2U24 and 2U12
D1012/D1024 Hardware Installation and Maintenance Guide
Where to find procedure
See the rack-mount bracket kit installation instructions
pertaining to your enclosure. Also refer to the bezel
attachment instructions for your enclosure
See
Connecting Storage Enclosures
See
Connecting Storage Enclosures
See
Powering on/powering off
See
Testing enclosure connections
Refer to your RAID controller documentation.
on page 25.
on page 25
on page 27.
on page 26.
25

Advertisement

Table of Contents
loading

This manual is also suitable for:

D1024

Table of Contents