Input Pullup; Output Type; Output 1, 2, And 3 - Banner iVu Plus TG Series Instruction Manual

Ivu plus tg and color gen2 image sensors
Table of Contents

Advertisement

iVu Plus TG and Color Gen2 Image Sensors

11.6.2 Input Pullup

Main Menu > System > Discrete I/O > Input Pullup
By default, the Input Pullup is disabled. If the device used to trigger and remote teach the iVu is a NPN device, enable Input
Pullup here if that device does not have its own pullup resistor. Otherwise, this should be disabled.

11.6.3 Output Type

Main Menu > System > Discrete I/O > Output Type
Select NPN to configure the device's outputs to sink current. Select PNP to configure the device's output for source
current.

11.6.4 Output 1, 2, and 3

Main Menu > System > Discrete I/O > Output (#)
Output 1, 2, and 3 are set up separately to improve flexibility and simplicity.
Output can be configured for Inspection Pass, Inspection Fail, Sensor Pass, Sensor Fail, Sort Pattern #1, Missed Trigger or
System Error.
A Missed Trigger condition occurs when a trigger is received while the iVu is busy inspecting the previous image. This
output signal is set to active state. This signal will be reset up on resetting the History on the statistics screen.
A System Error condition occurs when a fatal error is detected on the device. This output signal will be set to active state.
This signal can be reset upon resetting the History on the statistics screen, or executing a ClearSystemError command
through command channel.
The default setting is Inspection Pass and Latched for Output 1. If Pulsed is selected, the default Pulse width is 50 ms.
Note: For Latched, the signal is active until the results of an inspection cause a change in the signal
output.
70
Figure 83. Input Polarity Screen
Figure 84. Discrete I/O Menu