iVu Plus Quick Start Guide
P/N 154721 rev. A -- 10/8/2010

Advertisement

Table of Contents
loading

Summary of Contents for Banner iVu Plus

  • Page 1 Plus Quick Start Guide P/N 154721 rev. A -- 10/8/2010...
  • Page 2: Table Of Contents

    2.4 iVu Plus Communications ........................8 2.4.1 Communication Channels ......................8 3 Installing and Connecting the Sensor ................9 3.1 Cable Connections for the iVu Plus Sensor with a Remote Display ............10 4 Overview of Configuring a Sensor ..................11 4.1 Acquiring an Image ..........................11 4.2 Configuring A Sensor Type...
  • Page 3: Introduction

    1 Introduction The iVu Plus is used to monitor labels, parts, and packaging for type, size, orientation, shape, and location. The sensor has an integrated color touch screen display making installation, setup and configuration easy without requiring a PC. Quick Start Overview...
  • Page 4: Ivu Plus Major Features

    2.1 Demo Mode The first time you power up the iVu Plus sensor, it starts in Demo Mode. Demo Mode uses stored images and inspection parameters that demonstrate how the sensor is set up without having to worry about focus, lighting, or triggers. In this mode, you can learn how to make adjustments working with the four sensor types while observing how the adjustments affect the sensor results.
  • Page 5: Selecting A Sensor Type

    Plus Quick Start Guide 2.2.1 Selecting a Sensor Type When you exit Demo Mode, the sensor reboots with a single inspection with a Match sensor type by default. To change the Sensor Type: 1. Go to Main Menu > Inspection > Properties > Sensor Type This displays the Sensor Type menu options.
  • Page 6: Multiple Inspections

    Plus Quick Start Guide 2.3 Multiple Inspections The iVu Plus supports multiple inspections that facilitate storing and controlling up to 30 inspections of different Sensor Types. 2.3.1 Adding a New Inspection To Add a new stored inspection: 1. Go Main Menu > Inspection > Stored Inspections and click Add New.
  • Page 7: Changing Running Inspections

    Plus Quick Start Guide 2.3.2 Changing Running Inspections To change the running inspection: 1. From the Home screen, click the Yellow button in the top center of the screen that displays the currently running inspection to display all the stored inspections.
  • Page 8: Ivu Plus Communications

    2.4 iVu Plus Communications The iVu Plus provides for communicating with other devices via Ethernet or a UART serial communicatoins port (RS-232). In order to establish an Ethernet connection, the external device must be configured with the correct IP address and correct TCP port to communi- cate with the sensor.
  • Page 9: Installing And Connecting The Sensor

    3 Installing and Connecting the Sensor The iVu Plus sensor requires a bracket for mounting. Four brackets are available from Ban- ner. The brackets allow the sensor to be mounted either perpendicular to the part or at an adjustable angle.
  • Page 10: Cable Connections For The Ivu Plus Sensor With A Remote Display

    Plus Quick Start Guide 3.1 Cable Connections for the iVu Plus Sensor with a Remote Display The cable connections on the iVu sensor are shown below, and power I/O connections (B) are defined in the Power I/O Connections table below.
  • Page 11: Overview Of Configuring A Sensor

    Depending on the target, this may mean the Re-Run Auto-Exposure integral ring light is not the best choice and other Banner lights should be considered. (Optional • Adjust the mounting angle to provide the clearest image of the part features you are monitoring.
  • Page 12: Configuring A Sensor Type

    4.2.1 Setting External Trigger Mode By default the Trigger on the iVu Plus sensor is set to Internal. To maintain control over triggering, before configuring any of the Sensor Types, change this setting to External ( Main Menu > Imager > Trigger ). Then, use the Manual Trigger in the lower-right corner of the sreen to trigger the sensor while configuring the sensor.
  • Page 13: Configuring A Blemish Sensor

    Adjust settings as necessary and retest. 4.2.3 Configuring a Blemish Sensor The flow chart at left provides an overview of the steps to setting up an inspection on the iVu Plus sensor as a Blemish sensor. Start 1.
  • Page 14: Configuring A Match Sensor

    Adjust settings as necessary and retest. 4.2.4 Configuring a Match Sensor The flow chart at left provides an overview of the steps to setting up an inspection on the iVu Plus sensor as a Match sensor. Start 1.
  • Page 15: Configuring A Sort Sensor

    Plus Quick Start Guide 4.2.5 Configuring a Sort Sensor The flow chart at left provides an overview of the steps to set up and inspection on the iVu Plus sensor as a Sort sensor. Start 1. Make sure you use good parts for the inspection setup. Normally, each part will be centered in the field of view with the feature of interest surrounded by the Region of Interest (ROI), a blue rectangle.
  • Page 16 Plus Quick Start Guide 5. Set the Pass Criteria (assuming only two stored patterns): • Any Saved Pattern—Pass condition if the sensor matches either Pattern_1, Pattern_2, or both • All Saved Patterns—Pass condition if the sensor matches both Pattern_1 AND Pat- tern_2 •...