Pinout Of The Et 200X-Desina - Siemens SIMATIC ET 200X Manual

Distributed i/o device
Table of Contents

Advertisement

C.10

Pinout of the ET 200X-DESINA

Figure C-13 shows you the pinout of the ET 200X-DESINA using the example of
the BM 143-DESINA FO basic module.
The BM 143-DESINA RS485 basic module has the same pinout on the
PROFIBUS-DP connection (pins 5 and 6) but has copper conductors instead of
fiber-optic cables. The arrangement of sockets X1 to X8 is identical for all DESINA
basic and expansion modules with digital inputs and outputs.
X01
Supply
5
6
2
3
1
4
View of DESINA
connections
(fiber-optic cables)
Looping through
Figure C-13 Pinout of the ET 200X-DESINA
Socket
X1
1 Sensor supply output L+ (NS)
2 Diagnostic input or input with NC function.
X3
3 Grounding supply voltage
X5
4 Digital input or output (DESINA) channels 0, 2, 4 and 6
X7
5 not assigned
X2
1 Sensor supply output L+ (NS)
2 Diagnostic input or input with NC function.
X4
3 Grounding supply voltage
X6
4 Digital input or output (DESINA) channels 1, 3, 5 and 7
X8
5 not assigned
ET 200X Distributed I/O Device
EWA 4NEB 780601602-06
2
X1
1
5
4
X02
X3
X5
X7
5
6
2
3
1
4
Pinout of the 8-channel DI/DO
Dimesioned Drawings and Pinouts
X2
3
Socket
X4
X01
X6
Supply
(Supply voltage
for electronics/
sensors, actuators
PROFIBUS-DP)
X02
X8
Loop through
*
Non-switched supply voltage
** Switched load voltage
*** on the basis of the DESINA specification
Pinout
1 L+ (NS*)
2 M (NS*)
3 M (S**)
4 L+ (S**)
5 Signal A (RD***)
6 Signal B (TD***)
1 L+ (NS*)
2 M (NS*)
3 M (S**)
4 L+ (S**)
5 Signal A (RD***)
6 Signal B (TD***)
C-15

Advertisement

Table of Contents
loading