3. Remove the Ethernet cables (
not have Ethernet or USB ports. See Figure 69 on page 133).
4. Loosen the two blue captive thumbscrews (
5. Using the thumbscrews, slowly remove the controller from the module.
Installing the Base or Expansion controller card
Figure 70. Installing a Controller card
Important: Base and Expansion Module controller cards are keyed to fit in their respective modules only.
A Base Module controller card does not fit into an Expansion Module, and vice versa. If you encounter
resistance when the controller card is installed, make sure that you are installing the controller card into
the appropriate module.
1. Position the new controller card on the alignment rails.
2. Slide the controller card slowly into the module until it is flush with the back panel of the module.
3. Tighten the blue captive thumbscrews (
4. Replace the expansion interconnect cables (
the USB cable (
USB ports. See Figure 69 on page 133).
5. Plug in the AC power cables.
Powering on the library
Power on the library by pressing Power on the Base Module just below the Operator Panel. The green
light illuminates. When the library is powered on, it inventories the tape cartridges in the magazines,
checks the firmware version on all modules, and configures the tape drives. Then, the library confirms the
presence of the existing modules, and searches for any new modules.
Verifying the Base or Expansion controller card
1. Verify that the library has the most up-to-date firmware revision. To find the version of firmware that is
installed on the library, check the Library Properties page of the Management GUI or the Status >
Library page of the Operator Panel.
2. If the Base Module controller is replaced, upgrade the firmware if necessary. Update the firmware
from the Management GUI at Library > Actions > Update Library Firmware.
Important: If you are asked whether to retain the serial number, always select Yes.
3. Check the Attention light on the front panel and login to web interface and check the dashboard for
any alerts.
4. With the Operator Panel or the Management GUI, check for any events. The event that indicated that
the controller was faulty is cleared.
134 IBM TS4300 Tape Library Machine Type 3555: User's Guide
4
and
5
) and the USB cable (
1
3
) that were removed previously. (An Expansion Module does not have Ethernet or
3
), if present. (An Expansion Module does
1
) on the controller.
) with your fingers to secure it to the module.
2
and
6
), the Ethernet cable or cables (
4
and
5
), and