IBM TS4300 3555 User Manual page 130

Tape library
Table of Contents

Advertisement

Table 36. Warning events (continued)
Event Code
Message Text and Description
4093
Couldn't obtain an IP address from DHCP
server.
4095
Library test failed. Not enough valid
cartridges available for testing.
4098
System time synchronization with SNTP
failed.
4099
An unexpected reset of accessor was
detected.
4113
Move from drive failed.
4117
Drive disabled because no power supply
available.
4119
Drive disabled because internal IP address
unknown.
4120
No empty drive available for system test.
4121
No compatible media available for system
test.
4122
No cartridge available for slot to slot
exerciser test.
4123
No empty slot available for slot to slot
exerciser test.
4124
Drive or media statistics couldn't be
retrieved when the tape was unloaded.
4126
Cartridge was found in inaccessible slot of
lowermost unit.
4127
Drive was restarted because of canister
reset.
100 IBM TS4300 Tape Library Machine Type 3555: User's Guide
Details and Solution
• Check the network configuration settings and
check if the DHCP server is reachable.
• Use the network configuration menu or
unplug the network cable and plug it in after a
few seconds to trigger an automatic
reconfiguration of the network interface.
Load the cartridges into the library.
Check for valid SNTP server address in Time
configuration. If correct, ensure that the server
is reachable from your network and not
blocked by a firewall.
Ensure that the spooling cable is fully seated in
the base module and connected correctly to
the accessor assembly. If the error recurs,
replace the accessor assembly.
Check for labels or cartridge misalignments
that prevents the cartridge from coming out of
the slot or drive.
Remove all affected drives, insert, and power
up at least one power supply to the failing
module. Wait 10 seconds and put the drives
back into the module.
• Remove affected drive, wait 10 seconds, and
put it back into the module.
• Restart Library stack.
Make sure that at least one empty drive and
one compatible cartridge are available.
Make sure that at least one empty drive and
one compatible cartridge are in the drive.
Make sure that at least one cartridge and one
empty slot are in the library.
Make sure that at least one cartridge and one
empty slot are in the library.
Check for more warning tickets. Replace media
if media-related tape alert flags reported.
Bottom slots from the lowermost unit are
inaccessible to the accessor. Place the
cartridge in an upper slot.
Verify that the drive is installed properly in its
slot and thumb screws are tightened. If the
error persists, replace the drive.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents