3. Analogue Output (option : 4~20mA or 0~10V)

3-1. Analogue Output Connection

3-2. Specification
①. Output Current : 4~20mA (Output Range : 2~22mA)
②. Accuracy : More than 1/1,000
③. Temperature Co-efficiency : 0.01%℃
④. Max. Loaded Impedance : Max. 500Ω
※ When Weight display is "Zero", 4mA current will be output, when Weight display is "Full
Capacity", 20mA current will be output.

3-3. Circuit

1 :Out
2 :Com.
3 :N.A
4 : N.A
"LO" terminal is not a "GND", so this "LO"
terminal do not be connected with other "GND"
terminal on other devices.
No.1
No.2
34 / 44