Start Up Instructions - Pentair 1.0 Service Manual

Whole house acid neutralizing systems
Table of Contents

Advertisement

1. Confirm the system is plumbed in correctly: inlet on left, outlet on right.
2. If you made any mistakes, make the necessary corrections before continuing with startup procedure.
3. When turning the water back on to the house, leave system in bypass mode. Then turn the water on
to the house and check for leaks. Run the cold water in bathtub to flush debris and air from lines.
(Bathtubs do not have aerators that may plug with debris.)
4. Press the SCROLL button 2 times. The display will start a 10 second count down. At zero the motor
will start and advance valve to cycle 1 (backwash). SLOWLY open the INLET VALVE PARTIALLY to
purge the air from the tank without stressing the fresh media.
5. Allow to run until there is a steady flow of water at the drain. Once this occurs you may advance valve
to next cycle by pressing and holding briefly the SCROLL button.
6. Once the motor starts, release the SCROLL button. Valve will advance to cycle 3 (fast rinse). Open
the inlet valve fully and allow to run the full 3 minutes of cycle. Once regeneration is complete, open
the outlet valve.
7. Run a faucet on the hot water side until it runs cold to drain hot water tank. While the water is running,
check the gallons remaining on the home screen and verify that the number is decreasing. This will
confirm that the system is counting gallons. If you do not want to waste water and skip this step, it
will take some time to exchange all the untreated water in the plumbing and hot water tank.
8. The installation is now complete.