Start-Up Instructions

Follow these instructions exactly to prevent the lid from separating from the filter during system start-up or operation.
See IMPORTANT SAFETY INSTRUCTIONS, page ii.
1. Ensure the spring on the clamp ring is fully compressed, with coils touching.
2. Open the Manual Air Relief Valve by turning the top of the valve 1/4 turn
counterclockwise, until it snaps into the full open position. See FIGURE 6.
3. Stand clear of the filter, then start the pump.
4. Watch for proper operation. The system is not working properly if:
a. The pressure gauge indicates pressure before water out-flow appears.
b. A solid stream of water does not appear within 30 seconds after the
pump's inlet basket fills with water.
c. Water leaks from where the two halves of the filter come together.
If any of these conditions exist, shut off the pump immediately. Open the
manual air relief valve to relieve pressure and clean the valve (see Cleaning the
Manual Air Relief Valve, page 7). If the problem persists, call Pentair Technical
Service at (800) 831-7133 for assistance.
5. After a steady stream of water appears, close the manual air relief valve by turning
the valve cover assembly a quarter turn clockwise.
6. The first time the system is started up, fill out TABLE 1 on page 1 and the
corresponding label on the equipment:
a. Record the "Original Starting Pressure"
b. Fill in the pressure at which the filter should cleaned. This is approximately
10 psi higher than the "Original Starting Pressure".
c. If the system includes a variable speed pump, record "Original Pump
RPM".