Start Up Instructions - Pentair CARBON FILTRATION SYSTEM 1.0 Service Manual

Whole house
Hide thumbs Also See for CARBON FILTRATION SYSTEM 1.0:
Table of Contents

Advertisement

1. Confirm the system is plumbed in correctly: inlet on left, outlet on right.
2. If you made any mistakes, make the necessary corrections before continuing with startup procedure.
3. When turning the water back on to the house, leave system in bypass mode. Then turn the water on
to the house and check for leaks. Run the cold water in bathtub to flush debris and air from lines.
(Bathtubs do not have aerators that may plug with debris.)
4. Press the SCROLL button 2 times. The display will start a 10 second count down. At zero the motor
will start and advance valve to cycle 1 (backwash). SLOWLY open the INLET VALVE PARTIALLY to
purge the air from the tank without stressing the fresh carbon.
5. Allow to run until there is a steady flow of water at the drain. Once this occurs you may advance valve
to next cycle by pressing and holding briefly the SCROLL button.
6. Once the motor starts, release the SCROLL button. The valve will advance to cycle 3 (fast rinse).
Open the inlet valve fully and allow to run the full 3 minutes of cycle. Once regeneration is complete,
open the outlet valve.
7. Go to a faucet. Run the cold water 5-10 minutes and test for chlorine. Run cold water till 0ppm of
chlorine is achieved. While the water is running, check the gallons remaining on the home screen
and verify that the number is decreasing. This will confirm that the system is counting gallons.
8. Run a faucet on the hot water side until it runs cold to drain hot water tank. If you do not want to
waste water and skip this step, it will take some time to exchange all the untreated water in the
plumbing and hot water tank.
9. The installation is now complete.
SYSTEM START UP INSTRUCTIONS