Pentair 1.0 Service Manual
Pentair 1.0 Service Manual

Pentair 1.0 Service Manual

Whole house acid neutralizing systems

Advertisement

WHOLE HOUSE ACID NEUTRALIZING SYSTEMS
1.0, 1.5
SERVICE MANUAL

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 1.0 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Pentair 1.0

  • Page 1 WHOLE HOUSE ACID NEUTRALIZING SYSTEMS 1.0, 1.5 SERVICE MANUAL...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS System Information ............................3 Application limitations......................Annual Maintenance Requirements......................4 Pre-Installation Instructions ..........................4 Installation Instructions ..........................5-7 Control Information ............................8 Programming the Control ........................9-12 Understanding the Diagnostic Level ......................13 Start Up Instructions ..........................14 Exploded Views and Parts Lists ......................15-21 Troubleshooting Guide ..........................22-23 Warranty Information ..........................24...
  • Page 3: System Information

    You now own the finest Water Treatment System available to homeowners. To enjoy the maximum benefits of this system, please read the contents of this Owners Manual. SYSTEM INFORMATION POWER REQUIREMENTS The computer board receives power from an external wall-mount transformer, supplied with each system.
  • Page 4: Annual Maintenance Requirements

    RATE ( DIAMETER X HEIGHT) 1.0 cuft 10 X 44 6.0 gpm 6.0 gpm Pentair Acid Neutralizing System 1.0 1.5 cuft 10 X 54 7.0 gpm 6.0 gpm Pentair Acid Neutralizing System 1.5 Table 2 -- Order Number for the replacement media...
  • Page 5: Installation Instructions

    INSTALLATION INSTRUCTIONS 1. SAFETY PRECAUTIONS • To prevent accident or injury, do not hoist the unit over your shoulder. Use a hand truck to transport the unit. Note: Do not lay the unit on its side during transportation and/or installation. •...
  • Page 6 • In some homes, metal piping may serve as a ground connection for the home electrical system. Installing a Pentair Filter with its nonmetallic valve body will interrupt the ground connection. Whenever a system is installed on metallic plumbing, we recommend you use grounding pipe clamps and a ground cable to maintain continuity of the ground connection from the inlet to the outlet pipe.
  • Page 7 Special Attention for situations where a Filter and a Softener are installed together: When a whole house filter and a softener are installed side by side, the preferred approach is to run a separate drain line from each unit all the way to the point of termination. If this is not done, there is the potential for drain water from the filter to back feed through the softener and overfill the brine tank, especially when drain lines are run overhead.
  • Page 8: Control Information

    CONTROL INFORMATION POWER ON LED A green LED is ON when power is applied to the control and the microprocessor is operating properly. SERVICE REQUIRED If the message “For Service Call” or “Service Required” displays in the window of the control without showing the time of day, the control valve has encountered a problem, such as failure to reach the proper position during regeneration.
  • Page 9: Programming The Control

    HOW TO PROGRAM THE INSTALLER’S LEVEL KEY BUTTONS: SCROLL BUTTON UP ARROW POWER POWER DOWN ARROW To begin, verify that the control is in the Service Mode. Time of Day GL Remaining • Press the DOWN ARROW and hold it for 5 seconds; the control will display: System Check •...
  • Page 10 • If you do not want to change the phone number, leave this setting at NO. Press SCROLL to advance to the next setting. • To change the number, select YES; Press the UP or DOWN ARROW and then enter the service phone number.
  • Page 11 • To adjust the resreve, press the SCROLL BUTTON. Use the UP OR DOWN ARROW to set the reserve capacity in increments to 10 gallons, upto 70% capacity of the bed. • To calculate the reserve capacity, take the number of people in the home and multiply it by 70 gallons per day.
  • Page 12 7. CYCLE 3 - FAST RINSE/BRINE REFILL The control will display: FILL/RNS: 3 min • Press the UP or DOWN ARROW to change the length of the fast rinse. The setting range is 0 to 99 minutes (maximum limit). Note: In most applications, this setting will not need adjusting. Press the SCROLL BUTTON to advance to the next setting.
  • Page 13: Understanding The Diagnostic Level

    UNDERSTANDING THE DIAGNOSTIC LEVEL To begin, verify that the control is in the Service Mode. Time of Day GL Remaining • Press the UP ARROW and hold it for 5 seconds; the control will display: Regen _ Days Ago The control is now in the Diagnostic Level. Use the SCROLL BUTTON to advance to each diagnostic. If no button is pressed within 5 minutes, the display will return to the Service Mode.
  • Page 14: Start Up Instructions

    SYSTEM START UP INSTRUCTIONS 1. Confirm the system is plumbed in correctly: inlet on left, outlet on right. 2. If you made any mistakes, make the necessary corrections before continuing with startup procedure. 3. When turning the water back on to the house, leave system in bypass mode. Then turn the water on to the house and check for leaks.
  • Page 15: Exploded Views And Parts Lists

    BYPASS VALVE EXPLODED VIEW AND PARTS LIST BYPASS VALVE ASSEMBLY PART NUMBER 72668 ITEM QUANTITY PART NUMBER DESCRIPTION 72599 SCREW 6X32X1/2 TYPE 72580 BYPASS END CAP 541 13328 017 O-RING 8730 72584 RETAINING RING VS-15 71161 568-363 NUT, BYPASS VALVE 71162 568-364 RING, NUT RETAINER 71110...
  • Page 16 VALVE EXPLODED VIEW...
  • Page 17 VALVE PARTS LIST ITEM PART NUMBER DESCRIPTION 70793 3/4 NPTF TO 1/2 ID HOSE MALE ELBOW (OPTIONAL) 75075 BACKWASH FLOW CONTROL 6.0 GPM 72678 SCREW 1/4-20 X 1-1/4 LG HEX WASHER HD 71083 VALVE BODY COVER 70658 VALVE COVER O-RING 72327 TEFLON WASHER 70665...
  • Page 18 CONTROL EXPLODED VIEW...
  • Page 19 CONTROL PARTS LIST ITEM QUANTITY PART NUMBER DESCRIPTION 39497 FRONT COVER ASSY, PENTAIR ROTARY 38752 BOARD ASSY FILTER WITH 2 LINE DISPLAY 70618 SCREW #4-24 X 3/8 LG SELF-THREADING 72519 FLOW METER SENSOR CABLE NGC 72134 HEYCO BUSHING, SR 5P-4...
  • Page 20 PART NUMBER DESCRIPTION 17485 10 X 44 TANK GRAY DH W/BASE 1.0 14598 10 X 54 TANK GRAY DH W/BASE 1.5 PENTAIR ROTARY VALVE ACID NEUTRALIZER 1.0 & 1.5 WITH 83491 BYPASS 18961 ACID NEUTRALIZER RISER PIPE ASSY 1.0 18962 ACID NEUTRALIZER RISER PIPE ASSY 1.5...
  • Page 21 Tank Size DIM A DIM B DIM C 10-1/4 in 51 in 10x44 46 in 10-1/4 in 55-7/8 in 61-1/4 in 10x54 3 in 8 3/4 in 14 1/2 in 4 3/4 in DIM A DIM C DIM B...
  • Page 22: Troubleshooting Guide

    TROUBLESHOOTING GUIDE SYMPTOM CAUSE SOLUTION 1. Untreated water to 1. Open bypass valve. 1. Close the bypass valve. service 2. Loss of filter media 2. Refer to SYMPTOM #4 3. The valve is in regeneration. 3. Wait for the regeneration to complete. 4.
  • Page 23 TROUBLESHOOTING GUIDE SYMPTOM CAUSE SOLUTION 3. The valve cycles Defective or shorted micorswitches Replace the microswitches. continuously. 1. Verify that the backwash flow control is 4. Loss of filter media 1. Excessive backwash/fast rinse flow. installed and sized correctly. through the drain line 2.
  • Page 24 Procedure for Obtaining Limited Warranty Coverage In order to obtain the benefits of this Limited Warranty, defective part(s) and/or product(s) must be returned to Pentair as soon as possible after discovery of the defect, but not later than the expiration date of the warranty period provided in this Limited Warranty.
  • Page 25 Notes...
  • Page 26 Notes...
  • Page 27 Notes...
  • Page 28 ©2020 Pentair Residential Filtration, LLC. All rights reserved. § For a detailed list of where Pentair trademarks are registered, please visit PENTAIR.COM/brands. Pentair trademarks and logos are owned by Pentair plc or its affiliates. Third party registered and unregistered trademarks and logos are the property of their respective owners.

This manual is also suitable for:

1.5

Table of Contents